Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The manual was very accurate for the part that I was changing, I was able to order the correct part and had no issues with the replacement procedure. However, I was expecting to have more detailed repairs for the lower drive unit.
 ;
I needed the manual immediately and I got it immediately. I couldn't find this manual anywhere else on the net. The site was easy to traverse, and the price was very reasonable. I'll definitely be back for any future needs.
 ;
I received a good service manual, with good resolution. Improve the instructions for the purchase because they are not well understood.
For the rest, so good.
Thanks Angel.
 ;
Very good documentation for the Grundig 2077 model (as well as similar 800/900/1000 series radios). The first two pages are a summary of reception specifications and output capability. The third page is the tuner dial indicator and dial cord routing diagram. the final ~5 pages are the schematics for the various models (including 2077). The scan quality of the schematics are good, adn can be easily read if zoomed in. The documents are in German, not English as stated. It would have been nice to have the tuning sequence and settings, and some trouble shooting materials... or component and wiring map.
 ;
Perfect like it was descriped, Perfect like it was descriped
TS4
6.1.2 Self-Diagnosis Mode
Procedure
1) Open the bonnet and short the Test Pin K6003 and GND. (The Test Pin terminal is located at the upper side of CN6002 as seen from the front.) 2) Turn ON the power. Push any key. The self-diagnosis mode is set. LED �0 to 33� on the IRD front panel light up one by one and then all lit. If a LED stops between �0 and 33�, the circuit block corresponding to that number should be checked. 3) When all the LEDs are lit, it indicates that the IRD is waiting for downloading of the Test software Main. The Test software Main will be downloaded from the PC connected to the IRD. 4) When the downloading completes normally, OK is displayed on the PC display. If OK, it indicates that the parallel port of the IRD is operating normally. 5) After completing the downloading, resetting the power supply, and this time all LEDs �0 to 33� will light up one by one, and finally all lit. If a LED stops, the circuit block corresponding to that number should be checked.
Example Downloading of Self-Diagnosis Program
1) Move the cursor to �Program Download� at MAKE CHECK_STEP, press the RETURN key and then press the F10 key to end the setting. When the IRD side sets into the downloading standby state, select IRD CHECK from the main menu, and press the RETURN key. Press the RETURN key once more to download the program.
2)
MAIN ASSY
Rear side
CN5005 CN5004 CN5003
IC2001 STi5510 Test Pin (K6003) [for Self-Diagnosis Mode]
Test Pin (K2002) [for Application Download Mode]
CN6002
Front side
Fig.1 Test Pin LOCATION
36
|
|
 |
> |
|