SERVICE MODE
4. Setting REGION code
4.1 While a highlighted indicator is displayed on the right side of the Region denotation, push ENT, and each button on the remote controller. With each push the indicator will advance as shown below.
Internal Setup Market 00 1 Region 1 Exit
00-WM 01-SFC 02-UK 03-XE 04-S18 05- SS 06-PA 07-AU 08-CN 09-JP 10-FXE 11-MX 13-NT
1 <-> 2 <-> 3 <-> 4 <-> 5 <-> 6
4.2 Specify the number of the model in accordance with the Market/Region Setup Table above. Region code of this mode is "1".
4.3 Once the desired number is displayed, push p button to move the highlighted indicator to Exit area.
(Reference figure)
5. Saving settings
5.1 Make sure that the Market and Region settings are properly set. (If any of the settings are incorrect, you can make a change by moving the indicator using o button, and following procedures 3 and 4 above. ) 5.2 After ensuring that the settings are all correct, push ENT button while the indicator is on Exit area. The settings are now saved.
Internal Setup Market Region 00 1
Exit
00-WM 01-SFC 02-UK 03-XE 04-S18 05- SS 06-PA 07-AU 08-CN 09-JP 10-FXE 11-MX 13-NT
(Reference figure)
6. Finishing settings
6.1 After a few seconds, the Internal Setup screen disappears, and then the Service Mode screen is displayed again for three seconds as shown on the right.
You should check the settings.
Region 1 Market WM BackendVersion S31204A2
S 31204 A 2
Backend version
Brand (S : SANYO , F : FISHER) Version ( 2 0 0 2 . 12 . 25) Sub Version (A,B,......Z) Region ( 0 : Region undefined 1 ~ 6 : Region defined ) Loader Version (17 Z09 Y03)
LoaderVersion
17 Z09 Y03
Value
(Reference figure) 6.2 Power OFF.
-4-
|
|
 |
> |
|