Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
More than pleased with my prurchase, very good product for the price.
 ;
This is a good quality scan of the service manual which includes an assembly diagram, block diagram, schematic, and parts list. Exactly what is needed to repair my KR-V55R receiver.
 ;
Excellent concise manual. All needed information was included. Typeface and diagrams were clear. Very fair price considering what others are charging. Many thanks
 ;
Response is a little slow- I had to wait 12 hours to receive download link but it says that it may take up to 24hrs.
Manual is old and was not produced in PDF- scanned copy is exellent.
Overall- value for money- I recommend
 ;
Excellent quality and quickly delivered manuals at a fair price. Great care is taken in the reproduction process. Even photographs and highly detailed drawings are as clear as in the original. That cannot be said for some freelance manual copies I have obtained from the web. If you have exhausted your internet search of technical manuals, try Owner-Manuals.com. If they do not have it, I do not think it exists. Perhaps, if requested, they may be able to find it. Their resources are certainly greater than most. Shopping here certainly beats waiting for months or years for the manual you seek to appear in an internet auction or garage sale.
1
2
3
4
1.3.8 Coefficient display of adjustment results
For some of the adjustments (FE and RF offset, FZD cancel, F and T gains, and RFAGC), the adjustment results can be displayed and confirmed in the test mode. The coefficient display in each auto adjustment is as follows: 1) FE and RF offset Reference value = 32 (coefficient of 32 indicates that no adjustment is required) The value is displayed in the unit of approximately 32 mV. Ex. When the FE offset coefficient is 35, 35 - 32 = 3 x 32 mV = 96 mV The correction is about +96 mV, which means the FE offset before adjustment is - 96 mV. 2) F and T gain adjustment Reference value for focus and tracking = 20
B
A
The displayed coefficient / the reference value indicates the adjusted gain. Ex. When the AGC coefficient is 40, adjustment of 40 / 20 = 2 times (+ 6 dB) has been performed. (It means that the original loop gain was half the target, and the whole gain was doubled to obtain the target value.) 3) RF level adjustment (RFAGC) Reference value = 8 The coefficient of 9 to 15 indicates to increase the RF level (for more gains). The coefficient of 7 to 10 indicates to decrease the RF level
C
(for less gains). When the coefficient changes by 1, the gain changes by 0.7 to 1 dB. When the coefficient is 15, the gain is the maximum at TYP + 7.9 dB. When the coefficient is 0, the gain is the minimum at TYP - 4.6 dB.
D
E
F
16
CX-3195
1 2 3 4
|
|
 |
> |
|