Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Very fast, clear and usefull site !
Also this Service Manual are very well maked and with a very good definition !
Very fast download speed !
Recomended Seller !
 ;
The manual you sent me was excellent. It included clear, readable diagrams and a usable parts list. I would surely use your service again. Thanks
 ;
Payments were processed quickly and items were exactly as described. I will use owner-manuals.com in the future for any other manual needs.
 ;
The Technics manual was very clear and I was able to solve my technical problems.
I did not think that anyone kept these manuals and was pleasantly surprised to find them on the Internet and at an affordable price.
I would recommend Owner Manuals as a first source of technical products for ‘dated’ equipment manuals.
Ian
 ;
The content of the manual was not found on the Internet and was a hard find. I check the net for 5 hours until I came across this web-site. When I did find the book it Auto loaded into my IPAD PDF shelf for books for review at anytime. Overall I am satisfied with the book and it answered all my questions. This repair book is obsolete because the product I bout it for is pretty old. Thanks for the help with the download and even having the manual. Thanks 73's K5HRD
5
6
7
8
1.3.5 RF level auto-adjustment (RFAGC)
This adjustment minimizes the dispersion of the RF level (RFO), which may be caused by disc-related errors, for more stable signal transmission by changing the amp gain between RFI and RFO. <Adjusting procedures> 1) The microcomputer sends the command to the servo LSI to read out the output from the RF level detecting circuit inside the servo LSI. 2) The microcomputer calculates the appropriate amp gain by using the output read out to adjust the RFO level at the prescribed one. 3) The microcomputer sends the command to the servo LSI to adjust the amp gain into the calculated one. This adjustment is automatically performed when: 1) During the setting-up mode, only the focus close operation ends. 2) Immediately before the setting-up ends (or right before the play mode starts) 3) During the play mode, the focus loop is locked again after unlocked.
A
B
1.3.6 Preamplifier gain adjustment
In this adjustment, when the reflected beams from disc surface are extremely weak (ex. when the lens is dirty, and a CD-RW is loaded), the whole gain in the RFAMP block (FE, TE, and RF amplifiers) is increased by +6dB or +12dB. <Adjusting procedures> When the system senses that the reflected beams from disc surface are extremely weak during the setting-up mode, the whole RFAMP gain is increased by +6dB or +12dB. After the gain is changed, the setting-up mode is restarted. If the whole RFAMP gain is always increased to the +6dB level in the play mode, the +6dB level will be employed at the starting of the setting-up mode from the next playback.
Gain of entire RFAMP Play the CD-RW with the gain being set to +12dB + 12dB D
C
+ 6dB
yy y ;;
Play is started with +6dB judging the lens is stained E Play at +6dB increases due to stained lens or other reasons (the typical gain is employed for the initial setup) Time F
TYP
Fig.1.3.1 Pre-amp gain adjustment
CX-3057
15 7 8
5
6
|
|
 |
> |
|