Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Great Service Manual, Very Complete, as advertised, Perfect, Thanks!
 ;
Good quality service manual.It has helped me to fix my FV1800,particularly for replacing the dial cord.The scheme is on A3 format and very readable.Thank.Olivier.
 ;
This manual is complete and very readable.It was a great help for my two ICF5800L.The first one had the dial cord broken,and without the service manual it is impossible to replace it.Thank.Olivier.
 ;
This is a top quality manual. You couldn't get better if you had the original and scanned it yourself. Best price on the net as well. Diagrams are clear and complete, text is sharp and easy to read. Granted you don't get the manual the second you click pay, but the few hours you have to wait for it to be available for download isn't a problem at all. This is a very reliable company.
Very VERY pleased with the product, and will buy others. Thanks!
 ;
In a word AWESOME.
I never expected the quality and abundant content that I got with this manual. Everything you'd ever want to know from a service perspective is found in this manual, along with... as a bonus, operating instructions on how to use the unit. WOW. Very impressed with the quality of the manual. You won't be disappointed if you're looking for the EVS900 service manual.
5
6
7
8
1.3.5 RF level auto-adjustment (RFAGC)
This adjustment minimizes the dispersion of the RF level (RFO), which may be caused by disc-related errors, for more stable signal transmission by changing the amp gain between RFI and RFO. <Adjusting procedures> 1) The microcomputer sends the command to the servo LSI to read out the output from the RF level detecting circuit inside the servo LSI. 2) The microcomputer calculates the appropriate amp gain by using the output read out to adjust the RFO level at the prescribed one. 3) The microcomputer sends the command to the servo LSI to adjust the amp gain into the calculated one. This adjustment is automatically performed when: 1) During the setting-up mode, only the focus close operation ends. 2) Immediately before the setting-up ends (or right before the play mode starts) 3) During the play mode, the focus loop is locked again after unlocked.
A
B
1.3.6 Preamplifier gain adjustment
In this adjustment, when the reflected beams from disc surface are extremely weak (ex. when the lens is dirty, and a CD-RW is loaded), the whole gain in the RFAMP block (FE, TE, and RF amplifiers) is increased by +6dB or +12dB. <Adjusting procedures> When the system senses that the reflected beams from disc surface are extremely weak during the setting-up mode, the whole RFAMP gain is increased by +6dB or +12dB. After the gain is changed, the setting-up mode is restarted. If the whole RFAMP gain is always increased to the +6dB level in the play mode, the +6dB level will be employed at the starting of the setting-up mode from the next playback.
Gain of entire RFAMP Play the CD-RW with the gain being set to +12dB + 12dB D
C
+ 6dB
yy y ;;
Play is started with +6dB judging the lens is stained E Play at +6dB increases due to stained lens or other reasons (the typical gain is employed for the initial setup) Time F
TYP
Fig.1.3.1 Pre-amp gain adjustment
CX-3057
15 7 8
5
6
|
|
 |
> |
|