6.4 FREQUENCY CHECK FOR CLOCK
A
- PCL output
In the normal operation mode (with the detachable panel installed, the ACC switched ON, the standby mode cancelled), shift the TESTIN terminal (IC601 Pin 86) to H. The clock signal is output from the PCL terminal (IC601 Pin 37). The frequency of the clock signal is 625.0kHz that is one 32th of the fundamental frequency. The clock signal should be 625.0kHz. If the clock signal is out of the range, the X'tal (X601) should be replaced with new one.