There are currently no product reviews.
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
 ;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
5
6
7
8
7.1.3 TROUBLE SHOOTING � For RLTXJ only
When set Voltage selector to 120V in the RLTXJ model and had supplied voltage doubler (240V) wrong, and power did not enter normal.
Start
A
Does a primary side fuse (FU1: ACIN assy) blow out? No
Yes
Replace the fuse.
B
Remove the two connectors (CN104 and CN105) from the POWER Assy.
Turn the power ON
Yes
Are the following voltages normal? No
� CN104 - pin 5: +15V, pin 6: -15V � CN105 - pin 5: +15V, pin 6: -15V
C
Are the protector ICs (IC119. IC120, IC112, IC113, IC122-IC125) on the POWER Assy broken? No
Yes
Replace the ICs of the same rating.
Replace the diodes D117-D120 and IC101 on the POWER Assy.
D
No
Are the following voltages normal? Yes
� CN104 - pin 5: +15V, pin 6: -15V � CN105 - pin 5: +15V, pin 6: -15V
Connect the two connectors (CN104 and CN105) on the POWER Assy from the BUS1 and BUS2 Assys.
E
Turn the power ON
End
F
DJM-1000
5 6 7 8
129
|