Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Fully functional usable service manual. Considering the age of the manual and device quality was better than expected
 ;
Thank you very much, I've been very happy to find this manual on "Owner Manual". It's a perfect copy and it has been really useful for my work!
 ;
It took about 24-hours after my payment before I was able to get to the download. Apparently, payment processing is not 100% automated. That is no big deal, just be aware of that going in.
After I got to it, it was in good shape, easy to read, etc. Not some cheap FAX copy looking thing.
Also, this site was the cheapest I found. Another Plus!
 ;
Good price, very legible manual, exactly what I needed -- but had to wait a day to actually get the download of the manual. Would have preferred to download it immediately after payment rather than waiting for someone to "process" my order. I was surprised that I had to wait that long.
 ;
As the only source for this manual it rather rank quite high since it is well scanned and perfectly readable.
5
6
7
8
7.1.3 TROUBLE SHOOTING � For RLTXJ only
When set Voltage selector to 120V in the RLTXJ model and had supplied voltage doubler (240V) wrong, and power did not enter normal.
Start
A
Does a primary side fuse (FU1: ACIN assy) blow out? No
Yes
Replace the fuse.
B
Remove the two connectors (CN104 and CN105) from the POWER Assy.
Turn the power ON
Yes
Are the following voltages normal? No
� CN104 - pin 5: +15V, pin 6: -15V � CN105 - pin 5: +15V, pin 6: -15V
C
Are the protector ICs (IC119. IC120, IC112, IC113, IC122-IC125) on the POWER Assy broken? No
Yes
Replace the ICs of the same rating.
Replace the diodes D117-D120 and IC101 on the POWER Assy.
D
No
Are the following voltages normal? Yes
� CN104 - pin 5: +15V, pin 6: -15V � CN105 - pin 5: +15V, pin 6: -15V
Connect the two connectors (CN104 and CN105) on the POWER Assy from the BUS1 and BUS2 Assys.
E
Turn the power ON
End
F
DJM-1000
5 6 7 8