Item
Display
Frequency (MHz) CQ �446.050 �445.050 �435.050
Adjust Point
Adjust Range RF signal level: -2dBu
Condition
10. S meter-L
Sm-L
T E
V/M
Check that the BEEP sound be heard after pressing V/M. RF signal level: 10dBu
11. S meter-H
CQ Sm-H T E
�446.050 �445.050 �435.050 V/M
Check that the BEEP sound be heard after pressing V/M. Check that the BEEP sound be heard
12. Standard Voltage bAtt � V/M
after pressing V/M. (Power Supply: 6.0V) Check if it is set the code 5E.
13. Low Battery (AA Battery) bAt-1 � V/M
If it is set to other code, adjust to code 5E by using �/�. Check that the BEEP sound be heard after pressing V/M. Check if it is set the code 3E.
14. Low Battery (Li-ion Battery) bAt-2 � V/M
If it is set to other code, adjust to code 3E by using �/�. Check that the BEEP sound be heard after pressing V/M.
15. Aging
Press PTT to start Aging. AGInG Press PTT to finish Aging. (Power Supply: 6.0V)
Turn off the power switch when the adjustment finishes.
25
|
|
 |
> |
|