3.4.2.
INITIAL SETTINGS:
When you replace the Main PCB, be sure to perform the initial settings after achieving the adjustment by ordering the following procedure in accordance with model suffix of the unit. 1. IMPORTANT NOTICE: Before proceeding Initial settings, be sure to read the following CAUTIONS.
2. PROCEDURES: � Preparation. Proceed the picture back up from the unit (Refer to above "CAUTION 2") � Step 1. The temporary cancellation of initial setting: Set the mode dial to �[ P ]�. While keep pressing [ AF macro/Focus switch ] button and �[ Upper arrow Cursor ] button� simultaneously, turn the Power on. � Step 2. The cancellation of initial setting: Set the mode dial to �[ Playback ]�. Press [ AF macro/Focus switch ] button and �[ Upper arrow Cursor ] button� simultaneously, then turn the Power off. � Step 3. Turn the Power on: Set the mode dial to �[ P ]�, and then turn the Power on. � Step 4. Display the INITIAL SETTING: While keep pressing [ MENU ] and �[ Right arrow Cursor ] button� simultaneously, turn the Power off.