Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Very fast service, best quality of the service manual and the schematics
 ;
This service manual of the old video cassette recorder VT-LC50EM is very good readable even the tiniest numbers (i.e. IC-pins). The circuits are very clear. Many details of the schematic are very good described but in GERMAN language. Many schematic details - but complete at all. Common background information of several details are enclosed and physical knowledge of the TFT liquid crystal display for example. The manual lacks PCB drawings. If you understand german I would recommend this manual for you.
 ;
Hi, this is a very clear manual, nice copy, not quite up to the standard of the very best available but better than many others. I think the price was especially fair for a hard to find manual and I would certainly use this manual seller again. Recommended.
 ;
This schema available for me in good condition. I would highly recommend.
 ;
Thanks for this "hard to find" service manual.
I apreciate the good quality of scanning and the pages scanned in A3 format.
5
6
7
8
IMPORTANT THIS PIONEER APPARATUS LASER OF CLASS 1. SHOULD BE DONE BY INSTRUCTED PERSON. A
LASER DIODE CHARACTERISTICS CONTAINS MAXIMUM OUTPUT POWER: 5 mW WAVELENGTH: 780 � 785 nm
A
SERVICING OPERATION OF THE APPARATUS SPECIALLY
WARNING ! The AEL(accessible emission level) of the laser power output is less then CLASS 1 but the laser component is capable of emitting radiation exceeding the limit for CLASS 1. A specially instructed person should servicing operation of the apparatus.
B
DMP-555/WY only
(PRW1233)
(VRW1094)
C
DMP-555/TL only
(DRW2102)
D
Additional Laser Caution 1. Laser Interlock Mechanism The position of the switch (S510) for detecting loading completion is detected by the system microprocessor, and the design prevents laser diode oscillation when the switch is not in LPS1 terminal side (when the mechanism is not clamped and LPS1 signal is high level.) Thus, the interlock will no longer function if the switch is deliberately set to LPS1 terminal side. ( if LPS1 signal is low level ). In the test mode* the interlock mechanism will not function. Laser diode oscillation will continue, if pin 4 of AN8702NFH (IC800) on the CDPB ASSY is connected to GND, or else the terminals of Q600 are shorted to each other (fault condition). 2. When the cover is opened, close viewing of the objective lens with the naked eye will cause exposure to a Class 1 laser beam.
E
Printed on the Bottom Plate
* Refer to pages 71.
F
DMP-555
5 6 7 8
3
|
|
 |
> |
|