|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Great manual very clear copied. You are making an incredible job. I appreciate a lot the rapidity and your efficiency. Thanks a lot
 ;
Good pdf of the service manual for this unit. Includes disassembly instructions, full schematics, board layouts, parts lists and diagnostic information. Some information is in the pdf twice (single pages, and split pages), but that could be how it was originally generated by panasonic, or perhaps the idea is to make it eaiser to put onto 8.5 x 11" pages.
Information was exactly what I needed. Delivery was overnight (less than 12 hours) and I was happy with the process.
 ;
5 STARS for FAST DELIVERY, BEST PRICES and QUALITY PRODUCT. Item was exactly as described with superb resolution. Will definitely source all my future requirements from this website. Thanks a lot owner-manual.com!
 ;
OEM manual provided all schematics, board layouts and component specs necessary to facilitate unit maintenance. All pages were clear and readable.
 ;
Good condition and quality. Hard to find anywhere in Internet, only on this site.
5
6
7
8
IMPORTANT THIS PIONEER APPARATUS LASER OF CLASS 1. SHOULD BE DONE BY INSTRUCTED PERSON. A
LASER DIODE CHARACTERISTICS CONTAINS MAXIMUM OUTPUT POWER: 5 mW WAVELENGTH: 780 � 785 nm
A
SERVICING OPERATION OF THE APPARATUS SPECIALLY
WARNING ! The AEL(accessible emission level) of the laser power output is less then CLASS 1 but the laser component is capable of emitting radiation exceeding the limit for CLASS 1. A specially instructed person should servicing operation of the apparatus.
B
DMP-555/WY only
(PRW1233)
(VRW1094)
C
DMP-555/TL only
(DRW2102)
D
Additional Laser Caution 1. Laser Interlock Mechanism The position of the switch (S510) for detecting loading completion is detected by the system microprocessor, and the design prevents laser diode oscillation when the switch is not in LPS1 terminal side (when the mechanism is not clamped and LPS1 signal is high level.) Thus, the interlock will no longer function if the switch is deliberately set to LPS1 terminal side. ( if LPS1 signal is low level ). In the test mode* the interlock mechanism will not function. Laser diode oscillation will continue, if pin 4 of AN8702NFH (IC800) on the CDPB ASSY is connected to GND, or else the terminals of Q600 are shorted to each other (fault condition). 2. When the cover is opened, close viewing of the objective lens with the naked eye will cause exposure to a Class 1 laser beam.
E
Printed on the Bottom Plate
* Refer to pages 71.
F
DMP-555
5 6 7 8
3
|
|
 |
> |
|