Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The content of the manual was not found on the Internet and was a hard find. I check the net for 5 hours until I came across this web-site. When I did find the book it Auto loaded into my IPAD PDF shelf for books for review at anytime. Overall I am satisfied with the book and it answered all my questions. This repair book is obsolete because the product I bout it for is pretty old. Thanks for the help with the download and even having the manual. Thanks 73's K5HRD
 ;
Excellent manual including schematics. The service was great and the manual helped complete the job.
 ;
It was magic after so many years to still be able to source this info. It was equally amazing to return my Pioneer receiver to it near new sound quality AFTER NEARLY 30 YEARS! Thank you for this ability!
 ;
Very quick and easy website to use and fast download of manual, quality of manual is excellent and will be pleased to use this service again in the future, thanks so much!
 ;
Easy and secure way to get a complete service manual of a vintage hifi component. Only some parts of the print copy are dificult to read. Nice price!
DP-8020E/8020P/8016P
3. PWM Adjustment 1) Ensure that Ledger / A3 Size Paper is loaded in one of the Trays, and pull out the remaining trays (including the bypass tray) to disable them. 2) Press �FUNCTION�, �ORIGINAL SIZE�, and �3� keys sequentially to enter the Service Mode. 3) Press the "8" key to enter the F8 Mode (Service Adjustment). 4) Press the "START" key. 5) Press the "1", "8", and "SET" keys sequentially to enter the F8-18 "C18 PRT PWM ADJ. PTN.". 6) Press the "START" key to begin the LSU PWM Pattern Printing. Sample: 4 gray patches are visible in the illustration, the value of the uppermost patch position is "+2" in our example.
(-5)
(0) +2
(+5)
In our sample, 4 patches are visible.
Test Pattern
7) Press the "STOP" key. 8) Press the "6", and the "START" keys to enter the F6 Mode (Adjust Parameters). 9) Select "39 LSU Unit PWM ADJUST". 10) Press "SET" button, and enter the value of the gray patch, as established in Step (6). 4. LSU Adjustment Refer to 2.9.
58