Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
It was helpful to get schematic with waveforms in important points and lot of service information. Manual is good quality, fast delivered. Of course it is hardcopy of paper one with all its disadvantages.
 ;
I want to give you a real heads-up for your desire to enable such people as I to acquire the information I need to maintain the older types of equipment such as this Akai HXA351W. You do a swell job with all the processes you have to perform so I can have a legible, thus usable
document which does not send me crazy trying to figure out the blurry text of a bad copy.
Very well done, Thomas.
 ;
This manual is very well presented and after printing out looks about as close to an original as I think you can get. The quality is second to none.
The content of the manual is comprehensive and I think it would be well suited to an audio repair professional which I'm not but I did find it very informative and helpful.
The cost of the manual is more than covered by the money I'll save when I change the keep memory battery now I have the relavant info.
Very pleased with my purchase and can recommend it wholeheartedly as I can other manuals I've downloaded from this site.
Regards
Limey Alex
 ;
Complete manual including mechanical part in good pdf quality. Shaded greys of the pcb due to pdf not perfect but usable.
 ;
Nice pdf file of the manual sent promptly. Thanks.
CD-403/403-S/404/406/DPF-R3030/R3030-S/R4030/R4030-S/R6030
ADJUSTMENT
No. ITEM INPUT SETTINGS OUTPUT SETTINGS PLAYER SETTINGS ALIGNMENT POINTS ALIGN FOR FIG.
Open the tray (Normal mode), then turn the power off. While pressing the REPEAT key, turn the AC ON. (Test mode) Press the PLAY/PAUSE key, then confirm that the display is "03". On the power from 0.08 to 0.15 mW, when the diffraction grating is correctly aligned with the RF level of 1.0 Vp-p or more.
1
LASER POWER
�
Apply the sensor section of optical power meter on the pickup lens.
�
(a)
1. Load a disc on disc 1 tray. 2. Turn the power off. 3. While pressing the REPEAT. key, turn the power ON to enter the Test mode. Connect an oscilloscope as follows. CH1: Connect the DC voltmeter to CN3(pin3 and 4) on X32. Press the PLAY/PAUSE key, then confirm that the display is "05". Press the PLAY/PAUSE key, then confirm that the display is 03 or 05.
1
FOCUS ERROR BIAS
Test disc Type 4
FE BIAS VR1
Optimum eye pattern
2
LASER CURRENT CHECK
Test disc Type 4
-
0.5±0.2V
Note: Type 4 disc : SONY YEDS-18 Test Disc or equivalent. LPF: Around 47 k�+ 390 pF or so. Step 1~4 are in Test Mode.
(a) Laser power
0.08~0.15 mW
Pickup
Optical power meter
5
|
|
 |
> |
|