Who's Online
There currently are 5704 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Exactly as described, a Service Manual complete with the schematics and PCB layout delivered in a timely manner. Many thanks for the great service.
;
some of the writing is a bit blur but the part in the schmatic was great and i have fixed the machine thanks
;
Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
;
I will definitely be back for more information when I need it.
;
The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
2-1-4. UV-46 Board
Remove the front door assembly. (Refer to Section 1-2-1.) Remove the ribbon door. (Refer to Section 1-2-2.) Remove the cabinet (L) assembly. (Refer to Section 1-2-3.) Remove the FT panel assembly. (Refer to Section 1-2-4.) Remove the ferrite holder. (Refer to Section 2-8.) Remove the DK-46 board. (Refer to Section 2-1-3.) Remove the paper eject guide assembly. (Refer to Section 2-3.) 8. Remove the switching regulator. (Refer to Section 2-2.) 9. Remove the F chassis assembly. (Refer to Section 2-4.) 10. Remove the two screws and two filament tapes, then remove the UV cover and UV-46 board in the direction shown by the arrow. 11. Disconnect the flexible flat cable from the connector (CN431) on the UV-46 board.
BTP 2.6 x 8 Flexible flat cable
2-1-5. MD-46 Board
Remove the ribbon door. (Refer to Section 1-2-2.) Remove the cabinet (L) assembly. (Refer to Section 1-2-3.) Remove the ferrite holder. (Refer to Section 2-8.) Disconnect the seven harnesses from the connectors (CN309, CN901, CN903, CN904, CN905, CN906 and CN908) and two flexible flat cables from the connectors (CN902 and CN910) on the MD-46 board. 5. Remove the three screws, then remove the MD-46 board. 1. 2. 3. 4.
1. 2. 3. 4. 5. 6. 7.
CN906 CN309 CN910
CN905
CN903
CN904 CN908
BTP 2.6 x 8
MD-46 board (Side A)
UV cover
CN902 BVTT 2.6 x 5
CN901
Flexible flat cable Harness
CN431 UV-46 board
Harnesses
Harnesses
Filament tapes
MD-46 board
Harness
Flexible flat cable
Cabinet (R) assembly
12. Install the UV-46 board in the reverse order of steps 1 to 11.
DPP-EX50 V1