Some of the pictures in this manual are a bit irritating. I had to dissassemble the unit and some of the screws have different threads, which is not mentioned in this manual. Also some of the drawings of the boards look different than the actual boards.
After all, the manual was very useful. I was able to recalibrate the capstan drive and it is working fine again.
 ;
This manual is very good. 303 pages scanned in a very high resolution. My camera has bad, leaking capacitors which all of the V5000 models are suffering from these days.
There is a huge part list with all capacitors, transistors etc. in this manual which helped me a lot. Otherwise I would not have been able to buy replacement parts.
The dissassembly guide is very enormous and detailed. Unlike on the Panasonic MS1 manual I downloaded here it actually looks like the real parts look. And the screws are labeled correctly, so you shouldn't have any left after the repair. ;)
 ;
has all the schematics you could need,and very well laid out format also has all part numbers along with an exploded view which is helpful
 ;
Very nice to have! Now it is no problem to understand how it is put together.
Helps me a lot.
 ;
good scans, all is clear. all pages in order. recommended
DP-SE7/SE7(G)/SE9
ADJUSTMENT
No. ITEM INPUT SETTINGS OUTPUT SETTINGS PLAYER SETTINGS ALIGNMENT POINTS ALIGN FOR FIG.
While pressing the "REPEAT" key, turn the AC ON. { Refer to test mode (MODE 0 0) } On the power from 0.08 to 0.15 mW, when the diffraction grating is correctly aligned with the RF level of 0.6 Vp-p or more.
1
LASER POWER
�
Apply the sensor section of optical power meter on the pickup lens.
Press the PLAY/PAUSE key, then confirm that the LED is "03".
�
(a)
2
FOCUS ERROR BIAS
Test disc Type 4
Connect an oscilloscope as follows. CH1 : RF (CN3 pin 1) CH2 : TE (CN3 pin 6)
Press the PLAY/PAUSE key, then confirm that the LED is "05".
FE BIAS VR2
Optimum eye pattern
3
TRACKING ERROR BALANCE
Test disc Type 4
Connect an oscilloscope as follows. CH1 : RF (CN3 pin 1) CH2 : TE (CN3 pin 6)
Press the PLAY/PAUSE key, then confirm that the LED is "03".
TE BALANCE VR1
Symmetry between upper and lower patterns
4
TRACKING GAIN
Test disc Type 4 Connect a LPF to CN3 Apply signal of pin 5-6 to which you 1.2 kHz, connect an oscilloscope 50mVrms to or AC voltmeters. CN3 pin 5-6.
Press the PLAY/PAUSE key, then confirm that the LED is "05".
TRACKING GAIN VR3
Two VTVMs should read the same value.
(e)
Note: Type 4 disc : SONY YEDS-18 Test Disc or equivalent.(KTD-0V) LPF: Around 47 k�+ 390 pF or so. Step 1~4 are in Test Mode.
(a) Laser power
0.08 ~ 0.15 mW
(e) Tracking gainn
CN3
1 2 3 RF FE1 FE2 VC TE2 TE1
VC L.P.F. L.P.F. + + VTVM VTVM
_
1.2 kHz 50 mVrms
4 5 6
+
Pickup
Optical power meter
7 S.S
ALIGNMENT POINTS
CN1
T-GAIN
TE-B
FE-B
VR3
VR1
VR2
6
|
|
 |
> |
|