Doubted for buy this manual as it is my first order here and at not have cover image, I assumed would haven't. However, within 24 hs, already possessed the link to download it. The manual are scanned correctly and have all what is needed. Includes adjustments and diagrams of all circuits. Very satisfied.
 ;
Really good quality, аll readable.! Wonderful work shop. I recommend to all!
 ;
Good quality service manual.The scheme is on A3 format and very readable.Thank you
 ;
Very good service-manual with clear electrical diagrams. Thanks you.
 ;
the manual is in quite good quality and it's in pdf. manual was send in less then 6h.
6. Bias Current Adjustment
1. Set Test tape (Type 1 tape: UD-1) into the unit, input 1.25 kHz/12.5 kHz 21mV signal to JK1 LINE IN and record this signal on the tape. 2. Playback the recorded signal, and adjust RT103L (Lch) and RT103R (Rch) so that the level difference between both frequencies becomes within the range of 28mV + 2dB ~ �0.5dB on the voltmeter at JK1 LINE OUT. Remark: Unable to monitor waveform at line out during recording mode.
|
|
 |
> |
|