Who's Online
There currently are 5620 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Manual was just as described!!! I odered it and in less than a day was able to download it and the text was clear and pages were all complete just as the original manual was. Purcashed this for a friend and they were more than happy. Perfect all around!
;
Excellent service and prompt delivery. But it's not a manual - only 4 pages wiring diagrams.
Thanks.
;
The manual I purchased was exactly what I needed to repair my Toshica television. The manual contained schematics and troubleshooting information that was very helpful.
;
Il download del Service Manual JVC HR 4100 non é stato eseguito
;
The Service Manual was just as expected, complete with schematics and I was able to download it in less than an hour after I ordered it. The only problem with these is that the schematics are hard to read due to the small font. I could remedy this by printing them on a larger printer.
5.4
Updating the firmware of the drive unit
� Firmware update disc supports only DVD-RAM media. � When firmware update is necessary, written discs are distributed by DIGITAL VIDEO STORAGE CATEGORY, CS group. (1) Turn the main body ON. (2) Load the update DVD-RAM disc on the tray and close the tray. (3) �READING� is displayed in the FL indicator and the update is started. (4) In a short while �READING� in the FL indicator disappears, open the tray to remove the disc and close the tray. (5) Turn the power OFF and pull out the power code from the wall socket, then plug the power cord into the wall socket again. (6) Set to the JIG mode and check the firmware version of the drive. 5.5 Taking out a disc <Method 1 > There is a forced tray eject mode with electrical operation. (1) Right after plugging in the power code (while �LOADING� is displayed), keep pressing the OPEN/CLOSE button of the main body. (2) Remove the disc as the tray is ejected in a short while. (3) Make sure to close the tray afterwards. <Method 2 > When the disc cannot be removed by operating above <Method 1 >, open the front door of the main body manually and directly press the EJECT button located in the lower right of the drive unit. <Method 3 > When neither <Method 1> nor <Method 2> can remove the disc, the tray can be ejected mechanically without turning the power on. (1) Open the front door of the main body manually. (2) Insert a fine wire (e.g. a straightened paper clip) into the hole in the lower part of the tray of the drive unit. (3) As the tray ejects a little, pull out the tray manually.
Front door
Tray
Hole EJECT Button
5.6 Exchanging the fitting As the fitting that comes with the service drive unit cannot be used, make sure to attach a service fitting when the drive unit is exchanged. The fitting that is removed from the old drive unit can be attached to the new drive unit. The fitting can be removed by pulling upwards while opening out the lower part of the fitting outwards.
Tray
Fitting
1-18 (No.YD026)
|
|
|
> |
|