Manual is in German but complete. I needed this one to fix a long lasting problem with the internal PSU of the camera. Most of the capacitors begin to leak after a few years wich results in the inability to power on the camera. When you try to turn it on the power led flickers and the unit directly turns off. Thanks to this manual I was able to locate all bad cap's and to dis- and reassemble the camera without any problems.
 ;
We received the manual in a timely manner and it was exactly what we were expecting.
DRM-1004, DR-R102
� Connections
Personal Computer (DOS/V Machine)
SCSI Cable Set the SCSI ID to "0".
+5V and +12V
DC Power Supply
CD-R DRIVE UNIT (DR-R102)
� Preparations
� Set the SCSI ID to "0". � Turn on the power to the drive, insert the destination disc in clamp-up state, manually clamp the disc and short-circuit the changer interface connector (CN502: pins 4 and 5). When stopping, reverse this procedure.
WIFB BOARD ASSY
Short-circuit
CN502
5
GND
4
XCLAMP
Rear
Note: Be sure to execute the diagnostic program always in DOS mode. The DOS window of Windows is unstable with the diagnostic program.
Test 1: Checking the playback performance of a pressed disc (Test item: CDT-304)
� Disc to use Test disc CDT-304 � Test contents Test Items
Number of C1 errors at the inner and outer peripheries Full-stroke seek time Random read time Transfer rate
Standard Values
Less than 22/second (The number of C2 errors is regarded as a reference.) 300 ms or less 210 ms or less 2700 Kbytes/s or more
� Check method Select "CDT-304" and execute it by pressing the "Space" key (takes approx. 1 minute). If all the items are within the standard value range, "OK" is displayed. (If any are out of the standard value range, "NG" will be displayed, and a warning will sound. Press the "Escape" key to cancel.)
20
|
|
 |
> |
|