Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
 ;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
APPENDIX IC DESCRIPTION
13
PIN NAME CW OUT
FUNCTION An output terminal for the continuous chroma sub-carrier frequency wave, with an amplitude of 0.7Vp-p (typ). Also the dc level shows chroma killer status, with a level of 3.5V for B/W and 1.5V for Color.
INTERFACE
14
RGB VCC(9V)
15
YS/YM SW /Spot killer
A Vcc terminal for RGB block, PIF det. Output and sound output circuit. Supply 9V. A terminal for switching of EXT RGB Mode and fast Half tone.
-
16 17 18
EXT.R IN EXT.G IN EXT.B IN
Input terminals for EXT RGB signals. The signals are clamped by capacitors, therefore the input impedance should be low, 100 ohms or less is recommended. For this input, the brightness and RGB contrast is adjustable, the ABL/ACL limits the output level. This ABL/ACL may be turned On and OFF. OFF : for small area like OSD ON : for large area like TELETEXT (input level 0.7Vp-p/100IRE) The GND terminal for Y/C circuit. Terminals for R/G/B signal output. Connect resistances to GND, for the current source if the slew rate is not enough. Due to the source current limitation, the resistances should be 2.0 or more.
19 20 21 22
Y/C GND R OUT G OUT B OUT
-
-6-
|
|
 |
> |
|