Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Categories
Information
Featured Product
Home >> DAEWOO >> DTF-2930K-100D Service Manual
 
 0 item(s) in your cart 

DAEWOO DTF-2930K-100D
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of DAEWOO DTF-2930K-100D Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 D8444 PHILIPS Service Manual by Herbert de Groot;
Good en helpfull black and white scanned Srfvice manual of the Philps D8444. Quick service and delivery
 RSM75 TECHNICS Service Manual by Rohit Chirodian;
Scan was really good quality, easy to read, download easy
 5050 SANSUI Service Manual by John McKenna;
very good manual as always. easy to read, detailed and includes schematic
 STRDE698 SONY Service Manual by Jeffrey Miller;
I'm very satisfied with your manual service. Your website made it easy to locate the correct manual. Also the quality is great and I never had a problem reading the fine details. Thanks again. Jeff Miller JM Electronics
 22GM758 PHILIPS Service Manual by Frank Herrmann;
Good quality service manual German user manual. German user manual This is a quality scan of a manual in excellent condition and is just as good as having the original manual in hand

Text excerpt from page 65 (click to view)
CP-850FX Service Manual 5.10 POWER SUPPLY (STR-W6754) - Functions of Each Terminal 5.10.1 Vcc Terminal (Pin 4) 5.10.1.1 Start-up Circuit The start-up circuit detects Vcc terminal (No.4 pin) voltage, and makes a control IC start and stop. The power supply of the control IC (Vcc terminal input) employs a circuit as shown in Fig.1. At start-up, C3 is charged through a start-up resistor R2. The R2 value needs to be set more than the holding current of

R2

P

the latch circuit (150µA Max), which is described later, to be flown at the minimum AC input. 1 However, where the R2 value is too high, the current charging D2 D 4 to C3 shall be reduced after AC input. Consequently, it takes VC C much time to reach the operation start-up voltage, so it is C3 D S/ N 3 GD required to monitor the capacity of C3 that is mentioned later simultaneously. The Vcc terminal voltage falls immediately after the control circuit starts its operation; however the voltage STRW6700 drop is reduced by the increase of the C3 capacity. Therefore, Fig.1. Start-up Circuit even if the auxiliary drive winding voltage is delayed in rising, �1 起��路 the Vcc terminal voltage does not fall up to the operation stop voltage to maintain the start-up operation. However, with larger capacity of C3, it takes much time, after AC input, to reach the operation start since the certain time is required to charge C3. In general, SMPS performs its operation properly with the value, C3 is 10 to 47µF, R2 is 47k to 150k Ohm for 100V wide input, and 82K to 330K Ohm for 200V narrow input for its start up. As shown in Fig.2, the circuit current which makes the control circuit start is regulated at 100µA MAX (Vcc = 15V, Ta = 25C), and higher value resister R2 is applicable to the circuit. Once the Vcc terminal voltage reaches 18.2V (TYP), the control circuit starts its operation by the Start-up Circuit, and current consumption shall be increased. Once the Vcc terminal voltage falls and it becomes lower than the operation stop voltage 9.6V (TYP) with the decrease of the Vcc terminal voltage, Under Voltage Lock Out (UVLO) circuits stops the controlling operation and returns to the start-up mode.
C IC

100 μ A M ( AX ) 9 .6 V (TYP ) 1V 5 1 .V 82 ( TYP )

ï¼¶C C

Fig.2. VCC Terminal� � 路 � CC � � VCC端 Vol. � Circuit Cur. I ���� ICC

Europe R&D

64

You might also want to buy

$4.99

SX-K700 TECHNICS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

CJ-V51 PIONEER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

GRAND PRIX ELECTRONIC 754 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-PR602 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

EV-S1000E SONY
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

GRAND PRIX ELECTRONIC 780 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG7330 PANASONIC
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

MECABLITZ 60 CT4 METZ
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…
>
Parse Time: 0.94 - Number of Queries: 133 - Query Time: 0.402