Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Complete original Service Manual in good (scan) quality!
 ;
Very good manual. Plenty of service information including alignment instructions. Clear circuit diagram. Excellent, thank you.
 ;
Good morning, the service manual you sent me was perfect.
Your service and answering are excellent.
I recomend this service.
Best regards.
 ;
I had been looking everywhere for a proper service manual for this VCR. Everywhere else that has this available for download has a very light version. This is the full service manual with all aspects that would interest anyone looking for the service manual for the AIWA HV-MX100 Worldwide VHS VCR. Great quality (as always). A winner hands down. Best Quality.
 ;
Top quality manual. Covers all aspects you'd expect in a top quality service manual for this Panasonic VHS VCR. The manual resolution is high. Another top quality manual from the only site worth downloading manuals from! If you're looking for a manual for the PV-9662 VHS VCR, this is the one you'll want to get!
6. GEOMETRY 6.1 VERTICAL CENTER
1) Set the TV to � NORMAL I�mode. 2) Enter the service mode. 3) Locate the cusor at � V.CENTER�then press � VOL +� or � VOL -�keys to adjust the center line with the mechanical center marks of the CRT.
6.2 VERTICAL SIZE
* The VERTICAL CENTER adjustment has to be done in advance. 1) Receive the Retma pattern. 2) Set the TV to � NORMAL I�mode. 3) Enter the service mode. 4) Locate the cursor at � V.SIZE�then press � VOL +� or � VOL -�keys to adjust the upper part of the picture.
6.3 HORIZONTAL CENTER
1) Apply a RETMA PATTERN signal. 2) Set the TV to � NORMAL I�mode. 3) Enter the service mode. 4) Locate the cursor at � H.CENTER�then press � VOL +� or � VOL -�keys to adjust the picture centering.
if EEPROM(I702) has been changed; - Option data has to be change and - all alignment function has to be readjusted * The initial state of adjustment are as follows; - V-Center, V-Size, H-Center, R, G, B, AFT = Center ( - AGC = * Service Remocon )
|
|
 |
> |
|