Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Yes thank you i got the file i was after. There was a slight problem in my communication but it all worked out well.
A job well done.
 ;
Great manual...really saved me. The only problem is that I thought I would be able to download it directly when I paid for it but never received the download instructions until the next morning. The board trace pages were somewhat light also: really need to turn up the contrast on the printer before printing them. The schematic page was great; very clear! Well worth the money.
 ;
I've been in the electronic business for a long time. I used to buy Sam's Photofact for my needs which intailed having to go to the store and paying about $20 for a package of 3 different units so I was forced to buy more than I needed just to get one.
Owner manual is just at your keyboard and the information is almost instantansouly and the cost is very reasonable. Easy to print out if needed or simply read off of the screen. The larger the screen the better for obvious reasons.
 ;
Very good manual, at a very good price. Received in a timely manner
 ;
Only thу cover has poor quality, internal material has excellent quality - exactly what I needed
Thanks!
10-2. CONVERGENCE ADJUSTMENTS
B. CIRCUMFERENCE CONVERGENCE ADJUSTMENT
NOTE : Before attempting any purity adjustments, the
receiver should be operated for at least 15 minutes. A. CENTER CONVERGENCE ADJUSTMENT 1) Receive crosshatch pattern with a crosshatch signal generator. 2) Adjust the BRIGHTNESS and CONTRAST Controls for a good picture. 3) Adjust two tabs of the 4-Pole Magnets to change the angle between them (See Fig. 3) and superimpose red and blue vertical lines in the center area of the picture screen. (See Fig. 4) 4) Turn both tabs at the same time keeping their angles constant to superimpose red and blue horizontal lines at the center of the screen. (See Fig. 4) 5) Adjust two tabs of 6-Pole Magnets to superimpose red/blue line with green on top of each other. Adjusting the angle affects the vertical lines and rotating both magnets affects the horizontal lines. 6) Repeat adjustments 3), 4), 5) keeping in mind red, green and blue movement, because 4-Pole Magnets and 6-Pole Magnets interact and make dot movement complex.
NOTE : This adjustment requires Rubber Wedge Kit.
1) Loosen the clamping screw on deflection yoke to allow the yoke to tilt. 2) Place a wedge as shown in figure 2 temporarily. (Do not remove cover paper on adhesive part of the wedge.) 3) Tilt front of the deflection yoke up or down to obtain better convergence in circumference. (See Fig. 4) Push the mounting wedge into the space between picture and the yoke to hold the yoke temporarily. 4) Place other wedge into bottom space and remove the cover paper to stick. 5) Tilt front of the yoke right or left to obtain better convergence in cicumference. (See Fig. 4) 6) Hold the yoke position and put another wedge in either upper space. Remove cover paper and stick the wedge on picture tube to hold the yoke. 7) Detach the temporarily mounted wedge and put it in another upper space. Stick it on picture tube to fix the yoke. 8) After placing three wedges, re-check overall convergence. Tighten the screw firmly to hold the yoke tightly in place. 9) Stick 3 adhesive tapes on wedges as shown in figur32.
4-POLE MAGNETS PURITY MAGNETS 4DJUST THE ANGLE (VERTICAL LINES)
CONSTANT
CONVERGENCE MAGNET ASSEMBLY
Fig. 3
ROTATE TWO TABS AT THE SAME TIME (HORIZONTAL LINES)
ADJUSTMENT OF MAGNET
BLUE RED
RED/BLUE GRN
BGR B G R B G R BGR RGB R G B BGR
BLUE RED
RED/BLUE GRN
R G B
4-Pole Magnets Movement
6-Pole Magnets Movement Incline the Yoke up(or down) Incline the Yoke right(or left)
Center Convergence by Convergence Magnets
Circumference Convergence by DEF. Yoke
Fig. 4 Dot Movement Pattern
12
|
|
 |
> |
|