Who's Online
There currently are 5810 guests and 1 member online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I was very glad recieving the service manal from You. Additionaly very fast. Extremaly nice servicing. Thanks very mach! Now my GX-220 working better, than it was made. Alexander from Moscow, Russia/
;
Sweet! I won the item on eBay and couldn't adjust the geometry or even keep a steady picure. This guide has the full schematics (not available anywhere else as far as I could tell), and was a bargain for the wealth of knowledge it contains. I hooked it up to my testing equipment, tweaked a few potentiometers and got it playing videogames in no time. Thanks!
;
It was just what I need to fix my old BMW's CD player. Very convenient also. Thank you.
;
Great Manual! It contains all the wiring schematics and mechanical exploded views that are essential for service and repair. I was surprised I even found this for such an old machine. Only wish I knew of this site many years ago.
;
Great manual very clear copied. You are making an incredible job. I appreciate a lot the rapidity and your efficiency. Thanks a lot
ALIGNMENT INSTRUCTIONS
2) FOCUS ADJUSTMENT � Turn in a local station and adjust the Focus Control knob (located on FBT) for best picture details at high light condition. 3) RF AGC DELAY ADJUSTMENT (S5) � Receive a good local channel. � Enter the service mode and select service adjustment S5. � You can see the OSD as shown in below.
IF AUTO VIDEOL RFAGCD FM.LEV AGC POINT A/D VALUE : 8DH
MOVE ADJUST RECALL : SET
CONTROL RFAGC START 7 10 20 3.75
� Select RFAGCD item, press the volume up or down button until noise or beat in picture disappears. � Press the DISPLAY button to memorize the data.
4) GEOMETRIC ADJUSTMENTS (S6) � Enter the service mode and select service adjustment S7. � Whenever you select the � using the volume up or down button, the screen is changing like this. S7� NORMAL BLACK WHITE100 WHITE60 CROSS
� Using the volume up or down button, select internal cross pattern. � Select service adjustment S6 � You can see the OSD as shown in below.
GEOMETRY H. PHASE 20 V. POSI V. SIZE V SC V LIN 29 70 3 23
MOVE ADJUST RECALL : SET
NO SD POWER OFF YES
4-1. Horizontal Position Adjustment � Select H.PHASE item, adjust H.PHASE data value to obtain proper horizontal centering of the internal cross pattern at the left and right of the screen. 4-2. Vertical Position Adjustment � Select V.POSI item, adjust V.POSI data value to center the raster properly on thescreen.