|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This SM is quiet scarce and hard to find it is an excellent Service manual, very clear to read and to print schematics and diagrams, Hi quality, Complete manual with no pages missing. I am very pleased with the manual and the fast service I have received. Great place to shop.
Good luck finding you manual...
 ;
Quick delivery, the document was usefull, although the copy was i little bit unclear in the details.
 ;
A complete and well done copy of the manual, at a not expansive price!
The delivery of the manual is very fast.
Thank you for all
 ;
Perfect quality. Was able to fix speed drifting on my Sansui Turntable using the service manual instructions for PLL adjustment.
 ;
I am very happy regarding the online purchase of this manual from Owner-Manuals.com as with this I could set right my Denon CD player and Amplifier.
I once again sincerely thank them for the prompt service which was rendered to me.
N. Shanker
For fast insertion on RIN, GIN, BIN inputs then brightness, contrast and white point RGB is possible
RGB output illustration during OSD mode During OSD, the DC level on RGB outputs is 200mV less then DC level on RGB outputs during black current measurement (contrast, brightness and white point RGB are inactive) � Blue stretcher The Blue stretcher can be divided into two stretch-frunction - the Standard blue stretcher - the Extended blue stretcher The blue stretcher reduces the R- and G- signals by 14% whenever the video signal exceeds a threshold level of 80%. The extended blue stretch With the extended blue stretch the reduction of the G-signal is 8% and for the R-signal it is 22% whenever the signal exceeds the threshold level of 80% When adjusting the white point be sure that the blue stetcher is inactive. In principal all features should be switched off during white point adjustments. � RGB output stages. Looking at the RGB output signals several DC-levels can be seen. The DC-levels of the H- and V-blanking are 0.5V below nominal black level of the video signal. At the end of the vertical blanking (line 19, 20, 21) the measuring pulses for Continuous Cathode (CCC)loop or two point black current stabilisation can be observed. These measuring pulses have three DC-levels: - A DC-level of-0.1V with respect to nominal black level during the leakage measurement (LO). This level is chosen so that it lies close to the black level in order to have an accurate measurement close to cut off voltage of the picture tube - A pulse of +0.25V with respect to nominal black level, which corresponds with a cathode current of 8µA - A pulse of 0.38V above nominal black level which corresponds with a cathode current of 20µA The pulse-levels of +0.25V and +0.38V can only be seen measured on alternating fields. The RGB blanking level tracks with the DC level of the black current measurement pulses. The RGB output stages supply the buffered RGB signals to pins 21, 20 and 19 respectively.
43
|
|
 |
> |
|