Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
This manual is accurate and of high quality. It is only volume 2 of the service manual. This is schematic, parts lists, and exploded mechanical drawings. The theory of operation and the diss-assembly instructions are in volume 1. The unit can be tricky to dis-assemble portions of so the volume 1 manual can be important. The product description of the manual is accurate but it does not say anything about volume 1 and the image of the front page does clearly say Volume 2.
 ;
Wellll again thank you very much fast and effective. Clear and well done for such an old TV!!!!
 ;
It has all the information you will need to fix it. The main circuit diagram is only A4 but being a PDF, you can print it to any size - I did it on two sheets of A3 and it didnt lose any detail - just made it readable when pinned up above the bench. I've found the fault, just need to buy some obscure bits to get it going again!
I cant fault the process, I paid for the manual in the morning and it was ready to download by lunch time.
 ;
Very good copy in a 54 pages PDF archive. This is my sixth purchase here. :)
 ;
Another excellent buy! File too clear and explanatory.
DTR-4.5
Confirmation of protection circuit
1. Confirmation of speaker relay
Confirm that the speaker relays turn ON approximately 5 seconds after the power switch is turned ON. Confirm that the speaker relays turn OFF immediately after the power switch is turned OFF.
2. How to enter Test Mode
1. To enter a test mode (Test 1 to 4), when the unit is turned on, hold down "CD" + "DISPLAY" buttons and then press "STANDBY/ON" button. 2. Press the respective designated buttons and make sure that your target mode starts. Left arrow key Right arrow key
Zone 2
Standby
Mode Test-1 Test-2 Test-3 Test-4
Button to be pressed "DVD" "VIDEO 1" "VIDEO 2" "VIDEO 3"
Message to be shown on the Front display "Test-1-00" "Test-2-00" "TUNER 82" "Test-4-00"
To move to the next step, press the right arrow key. When you enter Test-3, it is necessary to press this button once to see "Test-3-00" is shown. To move to the previous step, press the left arrow key. To exit, press "STANDBY/ON" button.
3.Confirmation of protection circuit
Check of Voltage detection 1. Enter Test-4 mode. 2. Press and release the right arrow key repeatedly until "TEST-4-21" is shown on the Front display. 3. See your unit automatically start to check each channel. During the check, the message on the display is changing as follows: Channel 1st Message 2nd Message FL+ TEST-4-21 Protect OK FR- TEST-4-22 Protect OK C+ TEST-4-23 Protect OK SL- TEST-4-24 Protect OK SR+ TEST-4-25 Protect OK SBL- TEST-4-26 Protect OK SBR+ TEST-4-27 Protect OK When the whole check is completed, "TEST-4-35" is shown. 4. Exit from the test mode. Check of Current detection 1. Enter Test-4 mode. 2. Press and release the right arrow key repeatedly until "TEST-4-35" is shown on the Front display. 3. Connect a 3 ohm hollow resistor to a speaker terminal for each channel and make sure that the speaker relay would not cut off. 4. Connect a 1.5 ohm hollow resistor to a speaker terminal for each channel and make sure that the speaker relay would cut off. 5. Exit from the test mode.
|
|
 |
> |
|