Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Categories
Information
Featured Product
Home >> INTEGRA >> DTR-7.8 Service Manual
 
 0 item(s) in your cart 

INTEGRA DTR-7.8
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of INTEGRA DTR-7.8 Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 A5000 GRUNDIG Service Manual by Alan Baverstock;
The Service Manual received was helpful. The electronic information is exactly what I needed.
 KX-880HX KENWOOD Service Manual by Hartmut Lachenmann;
The Manual was perfect. The deliverie was perfect. Thanks
 TX32PB50D PANASONIC Service Manual by DAVID SHEPHERD;
Found website easy to use and manual very clear. First class service
 SUV65A TECHNICS Service Manual by Angelo-Marco Farina;
The quality is quite good and clear. Nothing of the informations inside is lost during the digitalizing process
 STR-1800 SONY Service Manual by Peter Ramaekers;
Very good service, fast downloads and good manuals.

Text excerpt from page 186 (click to view)
DTR-7.8 OPERATION CHECK-4
Condition of Protect Mode
The unit will go into Protect mode under the following conditions. (T: Thermal sensor temperature)

1. Thermal condition
Immediately T <= -30 C or Immediately T > 110 C VOLH

2. DC voltage condition
The sum of dc voltage of 7 channel speaker outputs is more than 7 V.

3. Current condition
Protect will be On if speaker output ac current >= 35 A Protect will not be On if speaker output ac current >= 11.7 A This condition is equivalent to OPERATION CHECK-2. Refer to the page 2. Test wave form:

2 msec 2 msec

20 msec

Condition of Power Supply Voltage Control
The power supply voltage(VH, VM or VL) for power amplifiers is changed by the relays: RL6601, 6602, 6611, 6612 on NAPS-9040. VH > VM > VL T : Thermal sensor temperature VOLH : Pin #99 input voltage of Main microprocessor: Q7001 (Refer to SD-4:D5 and SD-8:D2 of SCHEMATIC DIAGRAMS) Conditions: Speaker imp. = 6 or 8 ohm VH: 0V < VOLH < 0.4V and T < 85 C VM: 0.4V < VOLH < 2.0V and T < 85 C VL: 2.0V < VOLH < 3.3V(Vcc) and T < 85 C VL: T > 85 C Speaker imp. = 4 ohm or BTL VM: 0V < VOLH < 0.4V and T < 85 C VL: 0.4V < VOLH < 2.0V and T < 85 C VL: 2.0V < VOLH < 3.3V(Vcc) and T < 85 C VL: T > 85 C

Condition of Cooling Fan Operation
The cooling fan will stop or rotate under the following conditions. Thermal Sensor Temperature(T) 0V 60 C STOP 0.4V STOP 2.0V MID HIGH HIGH HIGH SPEED SPEED SPEED SPEED MID HIGH HIGH SPEED SPEED SPEED 70 C 80 C Note: �VOLH=0.4V� is equivalent to 0.8W(8 ohm, 7 ch) �VOLH=2.0V� is equivalent to Max power(8 ohm, 3 ch)

STOP

LOW MID SPEED SPEED