|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
 ;
The manual is useful for trouble shooting for an old instrument. It saved money,and let me enjoy DIY.
 ;
Perfect source of information for replacing the HDD and performing general diagnostics.
 ;
Perfect source of information for replacing the HDD and performing general diagnostics.
 ;
Very good scanned copies. Quick response and reasonable price. Thanks for service!
5
6
7
8
Arrangement of the flexible cable for the pickup
: Conductive surface Note: Be sure to move the Pickup Assy-S to the innermost perimeter.
A
1 2 3
Fold the flexible cable inward at the position of the reference line. Attach the flexible cable of the pickup to the connector. Fold the flexible cable of the pickup with the backing inward.
7
Pass the flexible cable below the hook, and fold it back. Make sure that the cable does not have any slack
7
Reference line
2
3
1
Hook
B
Backing 97mm ± 2mm
Front Side
Bottom View
8 4
Pass the flexible cable through the hook not allowing any slack. Make sure there is no slack in the cable Reference line
Fold the flexible cable back at the hook. Make sure that the cable is loose Hook
C
8 4
Hook
D
5 6
Fold the flexible cable as indicated in the photo. Hook the part folded in Step 1 to the hook.
9 6
Fold the flexible cable along the hook.
5
9
Reference line Hook Hook
E
Pass the cable below the hook
F
DV-260-S
5 6 7 8
69
|
|
 |
> |
|