|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Easy to order the manual. Good quality and fast delivery.
 ;
The Service Manual for Sansui AU-9500 was very helpfull, in complete and in good printable condition.
Thanks.
 ;
Dear Sir,
Document is original service document of sharp. I had a problem with the door contacts. Fuses where blown. With the manual in a few minuts is was clear what the problem was.
Manual was of great help.
With kind regards,
Martie Verhoeven
The Netherlands.
 ;
The scan is clear and well readable with very few weaker spots, usually on black background with white letters, but with enough zoom those spots can be read.
Printout is clear, the manual is complete and has all pages scanned.
I would give 5 stars, except that it is not in color, and the schematic and PCB pages are scanned on multiple pages. The document is locked (except printing) so the pages can not be extracted to compose them together for printing on the large plotter
It is worth the price tag.
 ;
let's say first that i do not need to have a credit for my opinion, i am a retired sparkie and i voluteerd to fix an electronic device for a local "Youthgroup",as no diagram was present i checked the "net" and gambled on this site and paying some fee via PayPall, i was gladly surprised that the manual arrived as was stated, GOOD SHOW, and best wishes, John
DV-340, DV-343
15. Disc distinction threshold value (CD and unrecorded disc) Threshold value of the disc distinction. Distinguish it from CD if bigger than this value, and distinguish it from an unrecorded disc if small. 16. Current jitter value Indicate the value that was read in from the MY-CHIP in DVD, and indicate the value that was read in from the servo DSP in CD. 17. Focus balance setting value of L0 18. Focus balance setting value of L1 19. Current mechanism controller inside mode (it does not support in this unit) It can indicate to a maximum 10 modes. Indicate only a nest share of the mode. 20. Processing step of 11 inside modes (it does not support in this unit) It can grasp the current mode, the mode reaching it and transition of step by watching 19 and 20. 21. Spindle control state of MY-CHIP (it does not support in this unit) OFF : Motor off condition A/B : Accelerator and brakes FG : FG servo RVP : Rough speed phase servo ORVP : Rough speed phase servo of offset addition 22. Rotation number of spindle motor Do not FG read in ? indication (during spindle stop). 23. Tracking error generation system (it does not support in this unit) 1: 1 beam (DPD) 3: 3 beams 24. TZC count value (it does not support in this unit) The value that counted the number of TZC for one rotation in the tracking open state. When this value is more than 512 with CD, set it in 1 beam because the eccentric is large. DVD does not measure it because it is 1 beam fixed (indication is 0000). 25. It indicates the frequency that entered the focus backup Hexadecimal number indication. Counter does not reset till turns the power off after turning it on. Due to a 1 byte counter, next of FF becomes 00. 26. It indicates focus backup limit frequency with the hexadecimal number Initial value is 14H, it does decrement whenever enter the focus backup and it gives up backup if it became 0. Then the error is generated. After reverted from the backup, When not enter the backup and pass fixed time (1500ms), return to initial value again.
27. It indicates the frequency that entered the internal circumference plunging into backup of the sled Hexadecimal number indication. Counter does not reset till turns the power off after turning it on. Due to a 1 byte counter, next of FF becomes 00. 28. It indicates the frequency that entered the tracking overrun backup Hexadecimal number indication. Counter does not reset till turns the power off after turning it on. Due to a 1 byte counter, next of FF becomes 00. 29. It indicates the limit frequency of tracking overrun backup with a hexadecimal number Initial value is 03H, it does decrement whenever enter the tracking overrun backup and it gives up backup if it became 0. 30. It indicates the frequency that entered sled overrun backup Hexadecimal number indication. Counter does not reset till turns the power off after turning it on. Due to a 1 byte counter, next of FF becomes 00. 31. It indicates the limit frequency of sled overrun backup with a hexadecimal number Initial value is 03H, it does decrement whenever enter the sled overrun backup and it gives up backup if it became 0. 32. It indicates the frequency that entered the tracking close NG backup Hexadecimal number indication. Counter does not reset till turns the power off after turning it on. Next of FF is be a 1 byte counter in 00. The hexadecimal number indication which indicates the frequency that reads 33. ID/subQ, and entered NG backup Hexadecimal number indication. A counter does not reset it till cuts it off after turning it on. Due to a 1 byte counter, next of FF becomes 00. 34. An address to indicate in 35 Set it by using RS232.I (an address) Set it with DA. 35. Contents of an address indicated in 34.
43
|
|
 |
> |
|