The manual was very accurate for the part that I was changing, I was able to order the correct part and had no issues with the replacement procedure. However, I was expecting to have more detailed repairs for the lower drive unit.
Text excerpt from page 10 (click to view)
B
Display abnormal
START
Does the screen appear?
No
Check if voltage of screen F1 and F2 is 3.3V. Check if voltage of 34 pin of UPD16311 is -24V. Check grounded negative voltage of screen F1 and F2. Replace UPD16311.