Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Great and quick support. The maual was exactly what I was looking for and my problem
solved. Many thanks.
 ;
Very good service Within one day i received a pdf of the users manual and electric circuits so I was able to measure the different voltages in the printed circuit and find out the fault Payment was also reliable and easy.Without the manual i could not have repaired.So thanks to "Search for a manual"
 ;
you are doing great job guys.....my father ask me to find out the schematics of Sony KV25R1D to sort out the problem ..(he was electrical technician, and excperianced with TV and simillar stuff). finally he found the cause and change all necessary parts....now he has got working old dog..and is very happy!!... thank you all.. NB..he also saved the repair cost.
 ;
Perfect. Received my manual within 24 hours. Clear scan of the manual I needed. No problem.
 ;
Item as described, very well detailed manual with complete schematics. I've received the download information shortly after payment, very good support.
DV-37, DV-S77, DV-S737, DV-737, DV-737-K
FL
39
Description of Error
SGC converge timeout
Causes if with a DVD
SGC could not converge during detects the peak
Causes if with a CD
Operation of the
Open Stop
41 Spindle timeout
The unit did not enter Stop mode within 10 seconds of issuance of a Stop command. The spindle could not converge into within ± 12% of the target FG rotation speed within 10 seconds after spindle kick. The first time after startup (the first time after disc distinction), it doesn't become the number of the target rotation within five seconds. The first time after startup, detects the abnormal rotation number of high-speed continuously 3 loops. DVD: 5 to 9 mS , CD: 40 to 60 mS
48
Spindle FG transition timeout
Stops. (FG timeout)
49
Spindle PLL transition timeout
After the second times after startup, it doesn't become the number of the target rotation Stops. within five seconds. Detects the abnormal high-speed or low-speed rotations. DVD: 5 to ("73" is displayed during 9 mS , CD: 40 to 60 mS starting process.) Stops. ("73" is displayed during starting process.) Stop
4A Spindle lock timeout Spindle could not lock more than 1.5 seconds before start the AFB. Auto sequence timeout of peak ABUSY did not return within 1 second after the DDTCT (peak detection) command was sent. ABUSY did not return within 30 mS after the FJMPD (Focus jump 1 to 0) command was sent. ABUSY did not return within 30 mS after the FJMPU (Focus jump 0 to 1) command was sent. ABUSY did not return within 50 mS after the GSUMON (play-AGC-measuring) command was sent. ABUSY did not return within 2 seconds after the DJSRT (disc-sensing) command was sent. ABUSY did not return within 1 second after the TBLOFS (Internal ATB after the completion of external ATB) command was sent. ABUSY did not return within 500 mS after the TSON (tracking servo ON) command was sent. ABUSY did not return within 200 mS after the TBL (external ATB) command was sent. ABUSY did not return within 2 seconds after the FGN (focus gain adjustment) command was sent. ABUSY did not return within 2 seconds after TGN (tracking gain adjustment) command was sent. ABUSY did not return within 1 second after the CMDAVE (offset adjustment) command was sent.
51
Auto sequence 52 timeout of focus jump down 53 Auto sequence timeout of focus
Stop
Stop
54
Auto sequence timeout of play AGC Auto sequence 55 timeout of disc-typesensing Auto sequence 56 timeout of ATB2
Stop Stop
Stop
Auto sequence 57 timeout of tracking servo ON Auto sequence 58 timeout of ATB1 Auto sequence 59 timeout of focus gain adjustment Auto sequence 5A timeout of tracking gain adjustment Auto sequence 5B timeout of offset adjustment Auto sequence 5C timeout of modulation factor measurement Auto sequence 5D timeout of auto focus bias Auto sequence 5F already busy 62 Pause retry error
Stop Stop Stop
Stop
Stop
ABUSY did not return within 200 mS after the ADJMIR (modulation factor measurement) command was sent. ABUSY did not return within 2 seconds after the AFB (auto focus bias) command was sent. A command could not be sent because ABUSY was low. ABUSY did not return within 200 mS after TLV command was sent. Pause mode could not be restored within three retries after it had been released.
Stop
Stop
Stop Continues operation
66
|
|
 |
> |
|