Very complete and well reading drawings. Documentation is essential for successful repairs.Good documentation, with all that is necessary. This manual was what I was waiting with all the information necessary for the repairing I need it for. You must buy it if you want to do repairs or simply understand how it works.
 ;
Excellent service manual includes everything is need to repair this radio-caseete, how to disassemble, wiring diagram, all , waiting time until the download was only a few hours. I'm going to buy service manuals from here, are cheap and very good.Thank you.
 ;
Good service manual,i saved from scrapping this deck,is now fully functional.Thanks.
 ;
Found this to be the manual included with the original packinging, was helpfull but did not give any detailed repair instructions.
 ;
Complete service manual, was very helpful in repairing this tapedeck.Thanks.
� Method-2 (In service mode or normal operation): Check the value of current flowing in the laser diode. 1. Remove the upper cabinet. 2. Read the current printed on the label attached on the rear side of the optical pick-up.
(Label stuck outside of the optical pick-up)
KSS-331C
24Y59
day
action number year month
� MAIN Board � (Side B)
SA350
Q501
Indicates current value. (In this case, 35.0 mA) A current value will vary depending on the set.
IC601
IC501 IC502
3. Connect a digital voltmeter as shown in Fig. 2. 4. Press the � key. 5. Calculate current value by the reading of the digital voltmeter. Reading of the digital voltmeter (V) ÷ 4.7 (�) = current value (A) (Example) Reading of the digital voltmeter of 0.1645 V: 0.1645 V ÷ 4.7 � = 0.035 (A) = 35 mA 6. Check that the current value is within the following range. � Current value of the label +5 mA (25�C) �11 Variation by temperature: 0.4 mA/�C Current increases with temperature increased. Current decreases with temperature decreased. If the current is more than the range above, there is a trouble in the automatic power control circuit or the laser diode is in deterioration. If less than the range, a trouble exists in the automatic power control circuit or the optical pick-up.
digital voltmeter
+ �
Fig. 2 Digital voltmeter connecting location