Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
It is wonderful done!!! a great job in scanning the manual. Superior quality in all the electric scheme. Very understandable and net!!! Thank you!
 ;
muy buen manual por lo completo de este algunos esquemas estan muy divididos lo que hace algo dificil el seguimiento.
 ;
very good manual, with detail and clarity in esquematic diagrams and waveforms .
 ;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
 ;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
EN 18 5.3
5.3.1
5.
DVD580M
Diagnostic Software, Trouble Shooting and Test Instructions
Fault Finding Trees
No Operation
Standby LED does not light, The player does not operates
Go
Check point : The output voltage of VCC is 5 V + / - 5 %. Observe: If the LED can be lighted up again when the R314 on front panel board is short circuit manually.
Yes
Solution: Replace the R314
No Check point : The 11V at the output of IC U201 pin number 3. Observe :N/A Yes Check point : The input side of R201 is over 11V. Observe :N/A No Check point : Short circuit the terminals of L 203 . Observe : The operation can be restored. No Solution : Replace the IC U201
Yes
Solution : Replace the resistor R201
Yes
Solution : Replace the coil L203
No
Check point : Short circuit the pin number 3 and 4 of the 201 L . Observe : The operation can be restored.
Yes
Solution : Replace the coil L201
No
Check point : Check the FUSE 2 01 Observe : FUSE is burn No
Solution : Yes Replace the FUSE
Replace the External PSU
CL 26532085-060.eps 180702