Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I was searching a way to modify the original phono-in entry (for connection of vynil disc player, with RIAA equalization) to a line-in entry (for connection of modern analog entries, eg. ipod, mp3player).
This service manual gave me the correct hints.
It contains very useful infos for repairing and modifing the hi-fi, such as disassembling instructions, block diagrams, schematic diagrams, PCB prints, replacement parts list.
Very good!
 ;
Great Job!!! clear and efficient as always!!
it is really nice to have peple that are doing such a good work!!!!!
 ;
I must admit, I was very skeptical... $4.99 for a 74 page service manual. I've seen some very poorly scanned manuals on the Internet, but this one is VERY good quality! Even when zooming into 500%. Great Deal!
 ;
Very good detail, Quick service response. A useful service manual with all details. I recomend this service.
 ;
As Always you can find here manuals even of difficult TV scheme which are scan in almost perfect way.clear and fast!!!!!
Great work thanks!
5
6
7
8
(2.2) Recording Power Adjustment
Objective
To optimize the playback power of laser diode (LD). A
Symptom when out of adjustment
When a gap is terrible : Player does not playback, track search is impossible When a gap is light : RF waveform is dirty. STOP
Measurement Instru- Shine the light emitted from the objective Player state
lens on the light power meter sensor. Wavelength 780nm Ave. mode
Adjustment location Set the value with the command Disc
None needed B
[Procedure]
[Write Power Low Adjustment]
"1AW"
Adjust with UP/DN command so that the indication of light power meter becomes 3.4 ± 0.1mW.
"EE"
(Store the adjustment value in the nonvolatile memory)
[Write Power High Adjustment]
"0AW"
Adjust with UP/DN command so that the indication of light power meter becomes 5.9 ± 0.1mW.
"EE"
(Store the adjustment value in the nonvolatile memory)
C
[Erase Power Low Adjustment]
"3AW" "EE"
Adjust with UP/DN command so that the indication of light power meter becomes 3.6 ± 0.1mW.
ment connections
(Store the adjustment value in the nonvolatile memory)
[Erase Power High Adjustment]
"2AW"
Adjust with UP/DN command so that the indication of light power meter becomes 6.5 ± 0.1mW.
"EE"
(Store the adjustment value in the nonvolatile memory)
D
[Erase Power APC Low Adjustment]
"2DT" (Selects CD-RW mode) "5AW"
Adjust with UP/DN command so that the indication of light power meter becomes 7.6 ± 0.1mW.
"EE"
(Store the adjustment value in the nonvolatile memory)
[Erase Power APC High Adjustment]
"4AW"
Adjust with UP/DN command so that the indication of light power meter becomes 15.1 ± 0.1mW.
"EE"
(Store the adjustment value in the nonvolatile memory)
E
[RW Erase Power Low Adjustment]
"7AW"
Adjust with UP/DN command so that the indication of light power meter becomes 5.3 ± 0.1mW.
"EE"
(Store the adjustment value in the nonvolatile memory)
[RW Erase Power High Adjustment]
"6AW"
Adjust with UP/DN command so that the indication of light power meter becomes 10.2 ± 0.1mW.
"EE"
(Store the adjustment value in the nonvolatile memory)
F
DVD-R7322
5 6 7 8
55
|
|
 |
> |
|