muy buen manual por lo completo de este algunos esquemas estan muy divididos lo que hace algo dificil el seguimiento.
;
very good manual, with detail and clarity in esquematic diagrams and waveforms .
;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
;
manual excelente completo , diagramas y esquemas bien presentados y buena calidad de imagen.
3-3. SERVO/SYSCON CIRCUIT
A.
Playback picture is not good.
Noise appears although adjusting tracking. YES
NO
Adjust tracking.
Noise shakes up and down on the screen.
NO
Noise appears although change cassette tape.
YES
Check and re-adjust the Path of Deck.
YES
Is CTL pulse applied to pin 73 of IC601?
NO
CTL HEAD height is normal and there is not dust.
NO
Adjust the HEAD height and remove dust.
YES
YES
Check circuit adjacent to IC601.
Is CTL pulse input to pin 71 and 72 of IC601?
NO
Check R523, R524 C508, C509.
YES
The voltage of pin 91 of IC601 is not changed. YES
NO
check R518 and C511.
Check IC601.