There are currently no product reviews.
 ;
Complete manual included schematics layouts and alignment procedure, clear to read and magnify, extremely pleased with manual and owner manual . com's service
 ;
perfect, i am very satisfait for the réception of the sansui r-5l service manual, thank you very much
 ;
Thank you, this is a rare document. Few others have it, but they charge way more for a download.
Great deal (even if you have to wait a few hours to get it).
 ;
The purchased manual is an high quality scan of the original Philips paper-based Service Manual. I am very satisfied!
 ;
The purchased manual is an scan of the original Panasonic paper-based Service Manual. Unfortunately the contrast is not perfect, but I am satisfied anyway!
5
6
7
8
9. Using torx driver (T2) (GGK1095) , In case of method 1: Turn the skew adjustment screw A slightly while monitoring RF waveform level in the oscilloscope and set the level to the maximum. At the middle periphery of pickup, turn the skew adjustment screw B slightly and set the level to the maximum. At the middle periphery of pickup, turn the skew adjustment screw A slightly again and set the level to the maximum. (Adjustments should be performed in the order of A, B, A, and please make sure each adjustment is completed as the screws turned to the right.) In case of method 2: Turn the skew adjustment screw A slightly while monitoring RF level in OSD and set the level to the maximum. At the middle periphery of pickup, turn the skew adjustment screw B slightly and set the level to the maximum. At the middle periphery of pickup, turn the skew adjustment screw A slightly again and set the level to the maximum. (Adjustments should be performed in the order of A, B, A, and please make sure each adjustment is completed as the screws turned to the right.)
A
B
B B A
A
C
[Criterion for Skew Adjustment OK] (DVD) Search inner periphery (ID: 40000) and outer periphery (ID: 200000), and respective error rate should be less than 1.000E - 3. If this is not satisfied, start over from step 9. (Disc used: GGV1025) Conduct a search after moving to the home position by CRG HOME, the error rate should be less than 2.500E - 3. If this is not satisfied, start over from step 9. (Disc used: TCD-782)
D
(CD)
* If the error rate does not fall within the abovementioned range by method 2, start over by method 1. 10. In FE Test Mode screen, after confirming the disc is stopped by Power OFF, eject the disc by Disc Eject.
E
F
DVH-P5000UB/XN/EW5
5 6
7
8
67
|