- Removing the pickup unit (Fig. 4)
1. Remove the module pc board in accordance with the procedure of "Removing the module pc board.� 2. While holding the pickup case, remove the skew screw (main). 3. Lifting the end of the pickup rack, slide the main shaft, and remove the pickup unit. Notes: Replacing the pickup unit requires the skew adjustment. Remove glue from both ends of the main and sub shafts, and skew stud. Do not reuse the old skew screw. Be sure to use a brand-new skew screw supplied with a new pickup unit. Fix the skew screw with glue (GYL1001) after adjustment.
A
B
Skew screw (main)
Skew screw Pickup unit Sub shaft
C
Skew screw
Fig. 4
D
E
F
CX-3078
5 6 7 8
19
|