|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
very good manual, with detail and clarity in esquematic diagrams and waveforms .
 ;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
 ;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
 ;
manual excelente completo , diagramas y esquemas bien presentados y buena calidad de imagen.
 ;
muy buen manual completo de buena calidad de impresion preciso y detallado , muy útil para la reparación.
DV-HR300S/HR350S DV-HR300H DV-HR300X
5-3. Notes for servicing
1. After replacing the HDD or main PWB, register the HDD-ID again. 2. After replacing I54R NOR flash (IC7502) or NAND flash (IC7509), upgrade the version using the CD. All the data in the HDD will be formatted by replacing the main PWB unit. The following parts cannot be replaced as the system information needs to be written. (Replace the PWB.) 1. EEPROM for I54R, IC7507 and IC7508 Setting procedure after replacement of HDD or main PWB 1) HDD installation The unit can be started after installing the HDD, but key operation is impossible since the HDD-ID is not registered. Perform HDD aging to register the HDD-ID. 2) HDD aging The test mode can be accessed after replacing the HDD. [1] Enter the test mode with the keys on the main unit (press the channel UP key and recording stop key simultaneously). [2] Enter �4� to open the drive screen. [3] Press the play key to enter the HDD aging mode. �0� appears on the LCD of the front panel. It increases to 58 and then changes to �777� when the aging is completed. Should �EEE� appear, replace the HDD and start the process over. Aging takes approx. 2.5 hours. [4] The aging is completed when �777� appears, and the HDD-ID is registered automatically. If the main PWB unit is replaced, enter the test mode and press the �10/0� key on the remote control to register the HDD-ID. [5] Restart the unit and check the operation. 3) Factory setting Initialize all the settings. Enter the test mode and press the �11� key on the remote control. The display stays black during the initialization process. Initialization is completed when the test mode appears on the LCD display following �507�.
5-4. Writing of software
1. Press the power key to turn on the power. 2. Open the tray with the tray open/close key and place the version upgrade CD. 3. Close the tray. Upgrade begins automatically. �200� appears on the main unit display. 4. When the upgrade finishes, the tray opens and �208� appears on the main unit display. 5. Turn off the power to complete the upgrade. � Upgrade the writer in the same way. In this case, �300� and �307� appear on the main unit display during the process.
12
|
|
 |
> |
|