Good service manual,i saved from scrapping this deck,is now fully functional.Thanks.
 ;
Found this to be the manual included with the original packinging, was helpfull but did not give any detailed repair instructions.
 ;
Complete service manual, was very helpful in repairing this tapedeck.Thanks.
 ;
The service manual was a copy of the original from Wirlpool. The quality was good, all neccecary information was available including the service-codenumbers, so I could order the right part to be replaced for repair.
Downloding was no probem after the payment.
Thanks for the service!
 ;
Good,readable manual. I found other manuals that were not readable when it came to part ID, but the one downloaded from owner-manual.com was better than expected. I will do buisness with owner-manual.com again.
2. PLAYBACK Y-SINGAL OUTPUT LEVEL Adj. Location RV396 Checking Point TP396 Measuring Equipment Oscilloscope Mode PB Test Tape DP-1
1) Playback the test tape (Color Bar Signal). 2) Connect the oscilloscope to TP396 and trigger the scope will a composite SYNC signal at TP313. 1) Adjust the scope so that it can display a waveform of approx. 2H. 3) Adjust RV396 to optain 2.0VP¡ 0.2 Vp-p between the SYNC TIP and 100% white level.
2.0¡ 0.2Vp-p
Horizontal 10Â¥s/div Vertical 0.5V/div.
3. SYNC TIP FREQUENCY Adj. Location RV391 Checking Point TP391 Measuring Equipment Oscilloscope Mode REC. Test Tape �¡
1) Set the unit to stop mode without video signal. (Jack of video line input is shorted with ground). 2) Conncet the frequency counter to TP391. 3) Adjust RV391 until the SYNC TIP frequency becomes 3.80 MHz¡ 0.1 MHz.
7
|
|
 |
> |
|