Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Easy to order the manual. Good quality and fast delivery.
 ;
The Service Manual for Sansui AU-9500 was very helpfull, in complete and in good printable condition.
Thanks.
 ;
Dear Sir,
Document is original service document of sharp. I had a problem with the door contacts. Fuses where blown. With the manual in a few minuts is was clear what the problem was.
Manual was of great help.
With kind regards,
Martie Verhoeven
The Netherlands.
 ;
The scan is clear and well readable with very few weaker spots, usually on black background with white letters, but with enough zoom those spots can be read.
Printout is clear, the manual is complete and has all pages scanned.
I would give 5 stars, except that it is not in color, and the schematic and PCB pages are scanned on multiple pages. The document is locked (except printing) so the pages can not be extracted to compose them together for printing on the large plotter
It is worth the price tag.
 ;
let's say first that i do not need to have a credit for my opinion, i am a retired sparkie and i voluteerd to fix an electronic device for a local "Youthgroup",as no diagram was present i checked the "net" and gambled on this site and paying some fee via PayPall, i was gladly surprised that the manual arrived as was stated, GOOD SHOW, and best wishes, John
1
2
3
4
2. SERIAL DOWNLOAD
[Purposes]
A
1. When the main board is replaced, the firmware versions for the system control computer, drive, and the TUFL microcomputer do not match, and operations of the unit may be destabilized. In such a case, the versions for the above three must be matched. 2. This method is used when disc downloading fails.
[Tools to be used]
� PC with serial port � RS-232C cross cable � RS-232C I/F jig (GGF1348) � 7P FFC (VDA1681) � Download program (Image Updater) (*) � Firmware (*) This program must be installed in advance.
[Connection]
Connect as follows:
PC
RS-232C cable
RS-232C I/F
7P FFC
This unit
B
[Install Procedures of the Download Program]
1 Expand the compressed data of SLoader zip. 2 The folder of Image Tools is created, and then double-click on Setup. Exe of that file.
C
3 When the selection screen of the driver is appeared, search from C drive as the driver is installed by default for windows 2000/XP.) 4 When the installation is finished, confirm that the Image Updater can select as [start] [Program] [EMMA2RL Turnkey Image Tools] [Image Updater].
[Download Procedures]
1 Connect the 232C I/F jigs above way.
D
2 Connect the FFC cable of the download jig to CN1402 of MAIN ASSY and the power cable to the unit. 3 Turn on the PC and set the communication baud rate of 232C to 115, 200 bps. 4 Initiate the Image Updater by selecting [Start] [Program] [EMMA2RL Turnkey Image Tools]
[Image Updater].
5 When the Image updater is initiated, select the port to the connecting port (COM1, etc). 6 Click [���] of the "Main Board" line on the extream right, and select the download program "DVR_231M.***file".
E
7 After selecting the download program, push the "Start" button. 8 When the status screen is displayed, turn the DVD recorder on. The writing of the firmware begins. (It's takes about 5 minutes for updating the firmware.) 9 After finishing the update, push "OK" button, and then finish the Image Updater by pushing "Stop" button. 0 Unplug the power cable first, and then the FFC cable. (Be sure tp keep this order.)
F
50