Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I'm very satisfied with your manual service. Your website made it easy to locate the correct manual. Also the quality is great and I never had a problem reading the fine details.
Thanks again.
Jeff Miller
JM Electronics
 ;
Good quality service manual German user manual. German user manual This is a quality scan of a manual in excellent condition and is just as good as having the original manual in hand
 ;
The manual for Sony LBT-D505 component stereo system is was excellent , with schematics, parts layout and parts list as well as instructions for adjustments for each component. Print was clear even when enlarged.
 ;
It's exactly a complete and very useful manual with all details what I needed. Thank you!I will come back whenever I need your manuals or schematics.
 ;
I searched EVERYWHERE looking for the manual/s on this "extinct" amp. Owner-Manuals.com made it available and for nearly nothing. Thanx to them, I can decipher the unknown cables and sort them out. Thanx, Owner-Manuals.com!!
1
2
3
4
2. SERIAL DOWNLOAD
[Purposes]
A
1. When the main board is replaced, the firmware versions for the system control computer, drive, and the TUFL microcomputer do not match, and operations of the unit may be destabilized. In such a case, the versions for the above three must be matched. 2. This method is used when disc downloading fails. � In the serial download, the stored code are not downloaded to HDD. After serial downloading, be sure to do disc download.
[Tools to be used]
B
[Connection]
Connect as follows:
* PC with serial port * RS-232C straight cable * RS-232C I/F jig (GGF1348) * 7P FFC (VDA1681) * Download program (UFU.exe) * Firmware
PC
RS-232C cable
RS-232C I/F
7P FFC
This unit
C
[Procedures]
1 Connect the 232C I/F jigs above way. 2 Turn on the PC and start the " UFU.exe ". 3 Select the Firmware file. ("sz0" file) 4 Turn the DVD recorder on and start the download program. " Target Device is connected " is appeared on the screen.
D
5 Select the Communication Speed (Baud Rate) a) Base Speed 38,400 b) Data Send Speed 115,200 6 START � Even if you click "START" button, sometimes "Communication Error" may come out one to twice, and download may fail. In this case, please click "START" again. � Other factors can be considerd if download fails 3 times or more. � And it takes about an hour for updating the firmware.
5
E
4
6
F
74
1 2
DVR-533H-S
3 4
|
|
 |
> |
|