Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Excellent quality, very quick download turnaround, will definately use again.
 ;
This is a awesome quality scan of the original Service Manual for Technics 8099.
Contains the circuit diagram, PCB layout, adjust/tune instructions as well.
Since this is my first buy here, i'm really glad! This site do works as intended/described, it's definitely not scam!
Мои рекомендации! Все мануалы настоящие!
 ;
Good Quality of the File.
You get the normal manual is incudet.
 ;
Very nice and real Service Manual, I didn't thought it actually exist in the real world at all.
 ;
VERY NICE FOR COURTESY AND PRECISION!.
tHE SITE IS VERY IMPORTANT FOR ALL DEVICES
vERY GOOD
5
6
7
8
6. ADJUSTMENT
[Purpose]
If the combination of MAIN Assy and LOADER Assy is changed, the adjusted value for LD power will be shifted, and stable playback or recording of a disc will become impossible. Therefore, when the combination of MAIN Assy and LOADER Assy is changed, LD power adjustment and adjustment for disc judgment will be necessary. Be sure to do this adjustment at following cases. � When replacing MAIN Assy � When replacing LOADER Assy
[Tools to be used]
� Special tool for adjusting the LD power (GGF1559) � 10-pin FFC flexible cable (GGD1477) � CD-ROM test disc: CDT-313 (GGV1054) � DVD dual-layer test disc: DVDT-002 (GGV1036)
A
[Notes]
Never turn the power off while any of the following operations is in progress: � While laser diode (LD) power adjustment is being performed normally by the unit � While adjustment for disc judgment is being performed
B
[Connections]
� Connections for adjusting the LD power
Special tool for adjusting the LD power
POWER SUPPLY Unit HDD
C
Main Assy and writer
Note: Before adjusting the LD power, disconnect the power to the HDD and the flexible cable for ATA (40-pin). � To which the special tool for adjusting the LD power is connected
The right side (see the figure below) of the connector is for connection of the flexible cable. CN5601
D
Main Assy
CN1402 CN1401
Special tool for adjusting the LD power
Connect the 10-pin flexible cable to the lower part of CN401.
� Setting of the switches on the special tool for adjusting the LD power
E
ON ON ON ON ON
Set all five switches to ON.
F
DVR-640H-AV
5 6 7 8