Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is a great site. I placed my order and by the next am it was available for download. Had some problems with some missing copy on some pages. Once I brought the error to the OMC's attention, the issue was resolved. I'll come back again.
 ;
Mi spiace per non poter scrivere in inglese... ma sono veramente soddisfatto del servizio offerto. Grazie..!!
 ;
The quality of this manual is good. It has all schematics and setup information for both the MDS-B3 and the MDS-B4. The scan quality is quite good, all pages are readable, This service manual also contains scans of the operating instructions from the User manual.
 ;
Quick site processing. A complete and very useful manual with all details. Thank you!
 ;
Das Service Manual war von der ersten bis zur letzten Seite sehr informativ und hilfreich. Die Darstellung aller Teile war klar und der Text gut lesbar.
Vielen Dank, das war nicht der letzte Download bei ownner-manuals.com.
1
2
3
4
2. SERIAL DOWNLOAD
[Purposes]
A
1. When the main board is replaced, the firmware versions for the system control computer, drive, and the TUFL microcomputer do not match, and operations of the unit may be destabilized. In such a case, the versions for the above three must be matched. 2. This method is used when disc downloading fails. � In the serial download, the stored code are not downloaded to HDD. After serial downloading, be sure to do disc download.
[Tools to be used]
B
[Connection]
Connect as follows:
* PC with serial port * RS-232C straight cable * RS-232C I/F jig (GGF1348) * 7P FFC (VDA1681) * Download program (UFU.exe) * Firmware
PC
RS-232C cable
RS-232C I/F
7P FFC
This unit
C
[Procedures]
1 Connect the 232C I/F jigs above way. 2 Turn on the PC and start the " UFU.exe ". 3 Select the Firmware file. ("sz0" file) 4 Turn the DVD recorder on and start the download program. " Target Device is connected " is appeared on the screen.
D
5 Select the Communication Speed (Baud Rate) a) Base Speed 38,400 b) Data Send Speed 115,200 6 START � Even if you click "START" button, sometimes "Communication Error" may come out one to twice, and download may fail. In this case, please click "START" again. � Other factors can be considerd if download fails 3 times or more. � And it takes about an hour for updating the firmware.
5
E
4
6
F
74
1 2
DVR-533H-S