3.1.4 INSPECTION (FAULT ANALYSIS PROGRAM) METHOD
Caution: Please use in the Real MS-DOS mode. (The program does not work in the MS-DOS prompt (DOS window) of the Windows.)
A
� Discs to be used
CD-ROM DVD-ROM (Single) DVD-ROM (Dual) CD-R CD-RW DVD-R DVD-RW DVD+R DVD+RW Recorded DVD-RAM : GGV1054 : GGV1035 : GGV1036 : GGV1126 (1x - 8x) : GGV1088 (Multi Speed), GGV1089(High Speed) : GGV1139 (1x) : GGV1170 (2x) : Richo (2.4x - 8x) : Richo (2.4x - 4x) : GGV1181
B
� Inspection program disc
FA Program Disc: GGS1054
� Installation method
Copy the program file "R7a_fa.exe" .
� Execution method
1. Start the PC in the MS-DOS mode. 2. Move to the directory to which the program file has been copied. Example: cd dvr107 [enter] (For "C:\dvr107") 3. Execute the program. r7a_fa /e /sv [enter]
C
Operation
To move the window To select the measurement item To execute the measurement To execute all items continuously To quit the program
Key Operation
Right or left cursor keys Up or down cursor keys Enter key Space key Esc key
Operation
To format F key 1. DVD-RW, 2. DVD+RW, 3. CD-RW
Key Operation
To select the drive unit 1. R7, 2. R6
M key
D
� Start-up screen
R7 for FA (GGS1054) r7a_fa.exe ver0.5
E
LDI Check
"OK" or "NG" is displayed here.
F
DVR-A07XLA
5 6 7 8