Execute Self-Test. Press the "3" key on the remote control unit for servicing while the menu screen is displayed. When the following screen is displayed, press the "1" key to start the Self-Test.
B
The progress of the test is displayed on the screen. The percentage remaining of the test is displayed on the screen, and the test is terminated when the percentage reaches 00%. Check whether or not an error has occurred after the test is finished. Diagnosis results � Without an error: ". . . Completed" is displayed. Then, proceed to the Extended Self-Test. � With an error: ". . . Error" is displayed. Look at the number in Test Result. If the place value for tens is 1 or 2, execute the Self-Test again. If it is from 3 to 7, the HDD must be replaced. Note: If the result of the second test is the same, replacement of the HDD is required.
C
Example: No error
D
Example: With an error
E
To return to the menu screen, press the "Clear" key.