SAFETY & PRECAUTIONS
SAFETY CHECK AFTER SERVING
Examine the area surrounding the repaired location for damage or deterioration. Observe that screw, parts and wires have been returned to original positions. Afterwards, perform the following tests and conform the specified values in order to verify compliance whit safety standards. 1. Insulation resistance test Confirm the specified insulation resistance between power cord plug prong and externally exposed parts of the set (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, earphone jacks, etc.) is greater than values given in table 1 below. 2. Dielectric strengthen test Confirm specified dielectric strengthen between power cord plug prongs and exposed accessible parts of the set (RF terminals, antenna terminals, video and audio input output terminals, microphone jack, ear phone jacks, etc.) is greater than values given table 1. 3. Clearance distance When replacing primary circuit component, confirm specified clearance distance (d), (d� between soldered terminals, ) and between terminals and surrounding metallic parts. See table below. Rating for selected areas
AC Line Voltage
100V 110 to 130V * 110 to 130V 200 to 240V Africa the middle east Southeast Asia
Region
Insulation Resistance $1M�/500V DC
-
Dielectric Strength
1kV AC 1min. 900V AC 1min. 4kV AC 1min.
Clearance Distance(d),(d� ) $3m $3.2mm $6mm(d) $8mm(d� ) (a :Power cord)
$10M�/500V DC
* : Class model only
NOTE
This table is unofficial and for reference only. Be sure to confirm the precise values for your particular country and locality