Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This manual is very good. 303 pages scanned in a very high resolution. My camera has bad, leaking capacitors which all of the V5000 models are suffering from these days.
There is a huge part list with all capacitors, transistors etc. in this manual which helped me a lot. Otherwise I would not have been able to buy replacement parts.
The dissassembly guide is very enormous and detailed. Unlike on the Panasonic MS1 manual I downloaded here it actually looks like the real parts look. And the screws are labeled correctly, so you shouldn't have any left after the repair. ;)
 ;
has all the schematics you could need,and very well laid out format also has all part numbers along with an exploded view which is helpful
 ;
Very nice to have! Now it is no problem to understand how it is put together.
Helps me a lot.
 ;
good scans, all is clear. all pages in order. recommended
 ;
Très-très bon site, facile, très bon prix.
Au futur besoin, je n’hésiterais à faire appel à vous.
Merci
SAFETY & PRECAUTIONS
SAFETY CHECK AFTER SERVING
Examine the area surrounding the repaired location for damage or deterioration. Observe that screw, parts and wires have been returned to original positions. Afterwards, perform the following tests and conform the specified values in order to verify compliance whit safety standards. 1. Insulation resistance test Confirm the specified insulation resistance between power cord plug prong and externally exposed parts of the set (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, earphone jacks, etc.) isgreater than values given in table 1 below. 2. Dielectric strengthen test Confirm specified dielectric strengthen between power cord plug prongs and exposed accessible parts of the set (RF terminals, antenna terminals, video and audio input output terminals, microphone jack, ear phone jacks, etc.) is greater than values given table 1. 3. Clearance distance When replacing primary circuit component, confirm specified clearance distance (d), (d� between soldered terminals, ) and between terminals and surrounding metallic parts. See table below. Rating for selected areas
AC Line Voltage
100V 110 to 130V * 110 to 130V 200 to 240V
Region
Japan USA & Canada Europe Australia Latin America
Insulation Resistance >1M�/500V DC
-
Dielectric Strength
1kV AC 1min. 900V AC 1min. 4kV AC 1min.
Clearance Distance(d),(d) >3 > 3.2 > 6(d) > 8(d') (a :Power cord)
>10M�/500V DC
* : Class model only
NOTE
This table is unofficial and for reference only. Be sure to confirm the precise values for your particular country and locality