Text excerpt from page 11 (click to view)
3-2-4. Horizontal Hold Adjustment
Note: When this adjustment is carried out, �3-2-2. Heater Voltage Pre-Adjustment� must be confirmed. Object: White Window chart
3-2-5. Focus Adjustment
Note: �3-2-6. Picture Frame Adjustment� and this adjustment affect each other. Repeat these adjustments until both specifications are met. Also, confirm �3-22.Heater Voltage Pre-Adjustment� .
Equipment: Waveform monitor, Oscilloscope Trigger: CH2/Oscilloscope Preparation: 1. Shoot the White Window chart and adjust the lens zoom so that the picture on the monitor screen becomes all white.
Monitor Screen
Object: Resolution chart Equipment: Waveform monitor Preparation: 1. IRIS AUTO/MANU (Lens) � MANU 2. BRIGHT control (Viewfinder) � Mechanical center 3. CONTRAST control (Viewfinder) � Fully clockwise 2 4. PEAKING control (Viewfinder) � Fully counterclockwise 3
Adjustment:
2. Adjust the iris control for the white level at VIDEO OUT connector on the camera is 100 ±2 IRE (PAL: 700 ±14 mV). Test point: CH1 TP4 (G1)/MAIN board CH2 TP9 (+H DEF)/MAIN board Adjusting point: 1RV5 (H-HOLD)/MAIN board Adjustment:
CH-1
1. Adjust the lens zoom so that the resolution chart frame coincides the underscanned picture frame on the monitor screen.
Monitor Screen
A CH-2 A=B
B
2. Adjust the iris control for the white level at VIDEO OUT connector on the camera is 100 ±2 IRE (PAL: 700 ±14 mV). 3. Adjust 1RV3 (FOCUS)/MAIN board so that the picture on the viewfinder screen is best focused.
TP1 TP3 TP2 TP4 TP5 TP6 TP7