I AM HIGHLY IMPRESSED BY THE EASE OF USE OF THIS DOWNLOAD SERVICE. INSTRUCTIONS ARE CLEAR AND SIMPLE TO FOLLOW....EVEN BY TECHNOPHOBES SUCH AS MYSELF. THE EMAILS POINT YOU IN THE RIGHT DIRECTION...ITS SO EASY PEASY. THE DOWNLOAD CHOICE OF USER MANUALS IS EXTENSIVE AND I COULD NOT FIND A CHEAPER OR MORE EFFICIENT SERVICE ON THE INTERNET. I COULD NOT HAVE MADE A BETTER CHOICE OF INFORMATION PROVIDER. SHOULD I EVER NEED ANOTHER USER MANUAL, THEN THIS IS THE FIRST CHOICE SITE. COULD NOT BE BETTER PLEASED!!!!!!!...MANY THANXES FROM JIM BURNS
I was impressed with the quality of service (frequent e-mails to let you know the status of your order), and the speed at which the download became available. The manual was a life saver and was not easy to track down. Thank you for such an excellent service.
the manual was just what i wanted it had all the revelent information required to operate the hifi .Iwould use any manual i downloaded for any item which needs a manual
Text excerpt from page 15 (click to view)
Insertion possibility
In case of insertion of the appliance between kitchen units, the dimensions to be respected are shown in fig. 14. When the kitchen is installed according to class 2, subclass 1 (i.e. built-in) for the gas connection use only flexible metallic tubes conforming to rules in force.
100
Fig. 14
FO 1076
Electrical connection
The unit is preset to work with a voltage of single phase 230 V. Before making the connection make sure that: � the energy power available in the user's house is sufficient for the normal supply of this appliance (see rating plate). � the unit is correctly connected to earth through a suitable plug and according to the installation country Laws. � the socket or the omnipolar switch used for the connection must be easilv reached with the installed appliance. The appliance is supplied with electric cord: you have to install a plug fit for the load shown in the serial number plate. The plug has to be connected to an adequate socket. If you wish to directly connect to the mains, you have to interpose an omnipolar switch with a minimum opening between contacts of 3 mm, between the unit and the mains, complying with the existing regulations. The brown live wire (originating from the clamp of the cooker junction box) must always be connected to the phase of the mains supply. In any case, the supply cord must be positioned in such a way as it doesn't reach in any point a temperature higher by 50°C than the room temperature.
500
Phase
Neutral wire
Fig. 15
FO 0480
Replacement of the supply cord
Should the supply cord need to be replaced, use only the following cable types: H05RR-F / H05VV-F / H05V2V2-F (T90). It is necessary that the yellow/green earth wire is about 2cm longer than the live and neutral ones (Fig. 15). about 3 minutes to ensure that they are working correctly.
After the connection, test the heating elements for
The manufacturer refuses any responsability in cases where normal safety measures are not observed.