I was so happy that the owner's manual was available. It is well written and helped me to use the radio/CD player/recorder without problems. Thanks for making it available.
Irene Lambert
Thanks so much for the Owner's manual for my Sony PS - FL1. I had purchased the turntable off of eBay. It came in and looked great. Packed well and appeared to be great. I balanced and aligned the tone are and hooked it up. When trying to play a record the tone are would move to the right place and just before it would drop to play it moved back off the edge of the record before touching down. I searched the net for an answer to this issue. No luck. Then I purchased the owners manual and sure enough there was a place to adjust where the stylus touched down. That adjustment solved the problem and saved me a $35 feet to have the player checked out. The manual is well written and easy to understand. It is a must have for anyone with this front loading Sony turntable.
Some years back I pruchased a Sansui G-9000. I had it cleaned up and a problem with the left channel repaired. When I got it back I hooked it up to my tape decks, turn tables, TV and it played great. The only thing I was not really satisfied with was the performance of my Graphic Equalizer. I purchased this owner's manual had poured myself a cup of coffee. The manual is well organized and written in plain language. It also contained the solution to my dissatisfaction. By using the preamp connections coupled I was able to run everything through my graphic equalizer and now enjoy the full potential of my complete system.
An excellent service for the price, however, it would also have been handy if the troubleshooter pages were included. The manual is only sent in the language of your country, thus it looks as though there are some pages missing. Otherwise highly recommended.
Text excerpt from page 3 (click to view)
PROTECTION VOLUME.- It is the volume situated within the horizontal planes previously stated for the prohibited volume plus another two vertical ones 1,00 meters away from those of the said volume. No switches, power sockets or lighting equipment must be installed within the PROHIBITED volume. Do not install switches within the PROTECTION volume; this does not apply, however, to safety power sockets. If possible the heater must be installed outside the PROHIBITED VOLUME so as to prevent water splashing against the unit. Power must be supplied via a multi-polar switch, circuit breaker
or contactor. Adequate power rating fuses shall be made available for unit protection purposes. All electrical installations shall incorporate an earthing connection. The plug used by the heater already has this connection and only has to be inserted in a mains socket of the same features. Make sure the household or place of installation does have an earth line. If not available, a differential switch is recommendable. The electric connection must be made with a power cable Type H05VVF 3x1,5 (Serie eco-R/RN).
OPERATION
Filling up. Open the shutoff cock as soon as the heater has been installed. Open the hot water taps. Water appears as soon as the unit fills up completely. Close the laps and check the system for leaks. Do not connect the heater to the power mains if uncertain as to whether it is foll or not. Electric connection. Plug into the mains and press the main power input switch. A light flashes when the heating element is activated (on some models). The thermostat re-connects the heating element after a certain amount of water has been used. Setting water temperatures. In the case of top-range models, the external control knob allows water temperature adjustments between 30°C (min. setting) and 70°C (max. setling). E Position. (Energy saving) the water reaches a temperature of approx. 55°C thus allowing the heater to operate economically. Heat losses are minimal and calcareous deposits are practically fully eliminated.
element
Heating element power setting switch. The deluxe and super deluxe models incorporate double power rating features and a switch for power setting changes: Pos. II; ; MAX.: Total power Pos. I; ; MIN.: Minimum power It is advisable to have the heater plugged into the mains permanently as the thermostat will only activate the unit when it becomes necessary to maintain the selected temperature settings. How to empty the unit. The heater should be fully drained if left unused for extended periods of time or if subject to freezing hazards where installed. This can be done by means of the safety valve (not safety valve eco). Always remember: - Cut-off the power supply - Shut-off the inqut cock - Open the hot water tap.
Therm.
MAINTENANCE
The heater does not require a special maintenance procedure. Clean by wiping with a soft cloth or damp sponge. Never use abrasives nor detergents. The customer is advised to contact the AFTER SALES SERVICE to check the magnesium bar once the guarantee has expired. Although this particular operation is not covered by the guarantee, as it does not imply «unit servicing», it does allow the wear rate of the bar to be monitored and to establish how soon it should be changed. Moreover, indefinite heater duration can be guaranteed.
Any overheating caused by thermostat failures is offset by the safety limiting device cutting both stages off and leaving the heater without power input. If this happens, contact our After Sales Service. WARNING.- Never remove the lead cover without previously disconnecting the heater from the power supply. THE MANUFACTURER reserves the right to modify the characteristics and specifications of all products wilhout prior notice.